SCCPStackQueueFull

Measurement Group: Server SCCP Exception

Measurement Type: Simple

Description: The number of ingress SCCP messages that were discarded because the SCCP Stack Event Queue was full.

Collection Interval: 30 min

Measurement Scope: NE, Server

Recovery:

  1. If both the peak and average measurement for multiple MPs within a Network Element are consistently near the recommended maximum engineered capacity of an MP over several collection intervals, then the number of MPs in the Network Element may need to be increased.
  2. If the peak and average for an individual MP are significantly different than other MPs in the same Network Element, then an MP-specific hardware, software, or configuration problem may exist.
  3. Contact My Oracle Support (MOS) for assistance if needed.