SS7ProcessPeak

Measurement Group: Server Resource Usage

Measurement Type: Max

Description: The peak SS7 Process CPU utilization (0-100%) measured during the collection interval. The SS7 Process is responsible for all SS7-related processing.

Collection Interval: 5 min

Peg Condition: The maximum SS7 Process CPU utilization sample taken during the collection interval.

Measurement Scope: NE, Server

Recovery:

  1. If both the peak and average measurement for multiple MPs within a Network Element are consistently near the recommended maximum engineered capacity of an MP over several collection intervals, then the number of MPs in the Network Element may need to be increased.
  2. If the peak and average for an individual MP is significantly different than other MPs in the same Network Element, then an MP-specific hardware, software, or configuration problem may exist or an STP/SG routing misconfiguration problem may exist.
  3. Contact My Oracle Support (MOS) for assistance if needed.