On the Policy and Charging > Configuration > Alarm Settings page on an SOAM, the user can view the configured Alarm Thresholds and Suppress indications.
Each alarm can be configured with Minor, Major, and Critical threshold percentages.
The fields are described in Alarm Settings elements.
The DSR Application Ingress Message Rate alarm is raised when the average Policy and Charging ingress messages rate exceeds the configured Alarm Threshold. The thresholds are based on the engineered system value for Ingress Message Capacity.
The SBR Sessions Threshold Exceeded alarm percent full is based on the number of Session records compared to an engineered maximum that varies according to the number of session SBR Server Groups per mated pair.
The SBR Sessions Threshold Exceeded alarm is raised when number of concurrent policy and Charging sessions exceeds the configured threshold.
The SBR Bindings Threshold Exceeded alarm measures the number of IMSI Anchor Key records against an engineered maximum value that varies according to the number of binding SBR Server Groups.
The Policy SBR Bindings Threshold Exceeded alarm works similarly to the session capacity alarm except that the scope of the binding capacity alarm is network-wide.