Error Codes elements

Table 2 describes the elements on the Policy add Charging > Configuration > Error Codes pages. Data Input Notes apply to the [Edit] page; the View page is read-only.

The Error Codes define the Result Codes to be returned for various Policy and Charging Error Conditions. Each Error Condition will return the Result Code configured for each applicable Diameter interface.

Table 1 indicates the Diameter interfaces that are supported for each Error Code.

The default Result Code is 3002-DIAMETER_UNABLE_TO_DELIVER.

Interfaces Supported for Each Error Code
Error Code Result Code Vendor ID
PCA Unavailable Or Degraded Gx/Gxx, Gx-Prime, Rx, S9, Gy/Ro Gx/Gxx, Gx-Prime, Rx, S9, Gy/Ro
PCA Functionality Unavailable or Disabled Gx/Gxx, Rx, S9, Gx-Prime, Gy/Ro Gx/Gxx, Rx, S9, Gx-Prime, Gy/Ro
Binding Not Found Rx, Gx-Prime Rx, Gx-Prime
Unable To Route Gx/Gxx,Gx-Prime, Rx, S9, Gy/Ro Gx/Gxx,Gx-Prime, Rx, S9, Gy/Ro
SBR Error Gx/Gxx,Gx-Prime, Rx, S9, Gy/Ro Gx/Gxx,Gx-Prime, Rx, S9, Gy/Ro
No Usable Keys In Binding Dependent Message Rx,Gx-Prime Rx,Gx-Prime
Session Not Found Gx/Gxx,Gx-Prime, Rx, S9, Gy/Ro Gx/Gxx,Gx-Prime, Rx, S9, Gy/Ro
Missing or Unconfigured APN Gx/Gxx, S9 Gx/Gxx, S9
Error Codes elements
Fields (* indicates required field) Description Data Input Notes
Error Condition The name of the selected Policy and Charging Error Condition. View only; cannot be edited
* Gx/Gxx, Result Code The Result Code to be returned on the Gx and Gxx interfaces.

Format: Text box

Range: 1-9999

Default: 3002

Gx/Gxx Vendor ID The Vendor ID that corresponds with the Gx and Gxx interfaces.

The Vendor ID '---' means the RFC standard error code will be sent.

Format: Text box

Range: 1-4294967295

* Rx Result Code The Result Code to be returned to the Rx interface.

Format: Text box

Range: 1-9999

Default: 3002

Rx Vendor ID The Vendor ID that corresponds with the Rx interface.

The Vendor ID '---' means the RFC standard error code will be sent.

Format: Text box

Range: 1-4294967295

* S9 Result Code The Result Code to be returned to the S9 interface.

Format: Text box

Range: 1-9999

Default: 3002

S9 Vendor ID The Vendor ID that corresponds the S9 interface.

The Vendor ID '---' means the RFC standard error code will be sent.

Format: Text box

Range: 1-4294967295

Gx-Prime Result Code The Result Code to be returned on the Gx-Prime interface

Format: Text Box

Range: 1-9999

Default: 3002

Gx-Prime Vendor ID The Vendor ID that corresponds with the Gx-Prime interface.

The Vendor ID '---' means the RFC standard error code will be sent.

Format: Text Box

Range: 1-4294967295

Gy/Ro Result Code The Result code to be returned on the Gy/Ro interface.

Format: Text Box

Range: 1-9999

Gy/Ro Vendor ID The Vendor ID which corresponds with the experimental code for the Gy/Ro interface.

Format: Text Box