Diameter Common Configuration for RBAR

The following Diameter Common configuration must be done before RBAR configuration can be performed.

Use the explanations and procedures in the Diameter Common configuration help and the Diameter Common User's Guide to complete the Diameter Common configuration, including the Diameter Common components needed for use with RBAR.

SOAM Diameter Common Configuration

Diameter Common configuration for MCC Ranges Network Identifiers and MP Profile assignment for RBAR is done from the SOAM GUI in a 3-tiered DSR topology.

  1. MPs

    Select Diameter Common > MPs > Profile Assignments, and verify that the correct Database MP Profiles have been assigned for RBAR DA-MPs shown in the DA-MP list. If assignments need to be made or changed, use the Diameter Common > MPs > Profile Assignments page to assign the correct MP Profiles.

    If RBAR and Policy DRA are running on the same DA-MP, select a Session_Database MP Profile.

  2. MCC Ranges

    Use the Diameter Common > Network Identifiers > MCC Ranges [Insert] page to specify up to 10 distinct, non-overlapping MCC Ranges.

    The following two MCC Ranges are reserved by telephony standards and are recommended to be created in addition to other specified ranges:
    1. 000-199
    2. 800-899

NOAM Diameter Common Configuration

Diameter Common configuration for MCCMNC and MCCMNC Mapping Network Identifiers for RBAR is done from the NOAM GUI in a 3-tiered DSR topology.
  1. Use the Diameter Common > Network Identifiers > MCCMNC [Insert] page to configure MCCMNC entries.