Operating Limits for FSPM Software

FSPM provides access over multiple data paths to LUNs defined on an Oracle FS System.

FSPM and the Oracle FS System operating software limits are described in the following table.
Table 1 FSPM operating limits
FSPM capabilities Maximum value
Target storage systems Eight for each FSPM host in any combination of Oracle FS Systems and Pillar Axiom systems
Connect to LUNs

Up to 256 for each Pillar Axiom system and 4096 for each Oracle FS System

Handle data paths 32 to each LUN
Handle FC HBA ports 32 for each SAN host
Important! Not all combinations of the operating limits were tested. If you configure an operating system to operate at or near these limits, the system might not work properly when these limits are used concurrently with each other.