1 NET 3 port to the Pilot NET 1 port | 3 NET 2 port to NET 2 port |
2 Cluster interconnect network port (labeled as <- - - >) to NET MGT port |
The following figure illustrates the cabling for SAN connectivity to the customer data network.
1 PCIe3 slot 1, HBA for SAN connectivity (FC or iSCSI) | 3 PCIe3 slot 5, HBA for SAN connectivity (FC or iSCSI) |
2 PCIe3 slot 4, HBA for SAN connectivity (FC or iSCSI) |
The SAS connections between the Controller HBAs provide access to the data path channels through HBA port 2 and port 3.
Controller 1 accesses the data path channels for I/O module 0 through direct SAS connections to the Drive Enclosure strings through HBA port 1 and port 2.
Controller 1 accesses the data path channels for I/O module 1 through Controller 2, HBA port 2 and port 3.
Controller 2 accesses the data path channel for I/O module 1 through direct SAS connections to the Drive Enclosure strings through HBA port 1 and port 2.
Controller 2 accesses the data path channels for I/O module 0 through Controller 1, HBA port 2 and port 3.
1 PCIe3 slot 3, SAS HBA port 2 and port 3 | 3 PCIe3 slot 2, SAS HBA port 2 and port 3 |
2 PCIe3 slot 6, SAS HBA port 2 and port 3 |
All of the SAS cables that connect Controller 1 to the Drive Enclosures attach to I/O module 0, port 0 on the Drive Enclosures. All of the SAS cables that connect Controller 2 to the Drive Enclosures attach to I/O module 1, port 0 on the Drive Enclosures
1 PCIe3 slot 3, SAS HBAs port 2 and port 3 connect the Controllers | 3 PCIe3 slot 3, SAS HBAs port 1 connects to Drive Enclosure string 2 |
2 PCIe3 slot 3, SAS HBAs port 0 connects to Drive Enclosure string 1 |
1 PCIe3 slot 2, SAS HBAs port 0 connects to Drive Enclosure string 3 | 6 PCIe3 slot 6, SAS HBAs port 1 connects to Drive Enclosure string 5 |
2 PCIe3 slot 2, SAS HBAs port 1 connects to Drive Enclosure string 6 | 7 PCIe3 slot 2, SAS HBAs port 2 and port 3 connect the Controllers |
3 PCIe3 slot 6, SAS HBAs port 0 connects to Drive Enclosure string 2 | 8 PCIe3 slot 6, SAS HBAs port 2 and port 3 connect the Controllers |
4 PCIe3 slot 3, SAS HBAs port 0 connects to Drive Enclosure string 1 | 9 PCIe3 slot 3, SAS HBAs port 2 and port 3 connect the Controllers |
5 PCIe3 slot 3, SAS HBAs port 1 connects to Drive Enclosure string 4 |