Types of External Cables

Customers must supply their own Ethernet cables for connecting the Pilots to the customer management network and for connecting the Controllers to the customer data network. Oracle has no cable color requirements for connecting the Oracle FS System to the customer network.

Pilot External Cables

Pilot external cables provide the management connections. Ethernet CAT6a cables connect from the NET 3 ports on the Pilot nodes to the customer management network. The connections to the customer management network must be to a highly available switch.

Controller External Cables

Controller external cables provide the connections for the host data path. Optical cables connect the SAN HBA ports on the Controller to the customer data network. Each connection requires an HBA and a specific SFP to provide the interface option.

The following table provides the part number and description of the SAN HBAs.
Table 1 SAN HBA

Part number

Description

7101673

Sun Storage 16Gb Fibre Channel PCIe Universal HBA, Qlogic, factory configure

The following table lists the SFP options.
Table 2 HBA options with SFPs

SFP option

SFP manufacturing part number

Description

16Gbs FC Optic SR

7023325

Used for Fibre Channel networks (includes one pair of SFPs)

10Gbs iSCSI Optic SR

7023315

Used for iSCSI (includes one pair of SFPs)

The SAN HBA ports on the Controller connect to SAN switches using optical cables (FC) or Ethernet cables (iSCSI) of specified lengths.

The following table summarizes the length limits for the optical cables that connect to the Controller SAN ports:
Table 3 Cable length limits for FC and iSCSI configurations

Speed

OM1

OM2

OM3

OM4

8 Gb/s

68.89 feet (21 meters)

164.042 feet (50 meters)

492.126 feet (150 meters)

623.36 feet (190 meters)

10 Gb/s (iSCSI)

108.268 feet (33 meters)

272.31 feet (83 meters)

984.252 feet (300 meters)

1804.46 feet (550 meters)

16 Gb/s

49.21 feet (15 meters)

114 .89 feet (35 meters)

328.084 feet (100 meters)

410.105 feet (125 meters)