There are two LEDs on each power supply. These LEDs are visible from the back of the Pilot.
Table 1 Pilot Drive LED status and description LED |
Icon |
LED color |
Status |
AC OK/DC OK
|
|
Green
|
OFF – No AC power is present.
SLOW BLINK – Normal operation. Input power is within specification. DC output voltage is not enabled.
STEADY ON – Normal operation. Input AC power and DC output voltage are within specification.
|
Service Required
|
|
Amber
|
OFF – Normal operation; no service required.
STEADY ON – The power supply (PS) has detected a PS fan failure, PS over-temperature, PS over current, or PS over or under voltage.
|