Engineering the power distribution unit (PDU) connections are the responsibility of the customer for not-racked systems. Also, component power cords must be installed into the component power supplies.
The C13 to C14 left-angled power cords used to connect Oracle FS System components to power distribution units (PDUs) are designed to keep the power cords snug against the PDU and to enable maximum access to the Oracle FS System components.
The Controller power cords are routed through the Controller cable management arms (CMAs), one for each Controller. Route the power supply (PS–1) to one source of external power and the power supply (PS–0) to another.
The Pilot power cords are routed through the Pilot CMAs, one for each Pilot.
1 Pilot power cords plugged into left PDU |
2 Pilot power cords plugged into right PDU |
3 CMA |
The power cords for the Drive Enclosures are routed directly to the PDU outlets without the use of CMAs. Any excess cable is fastened to the outside of the vertical rail that is nearest to the power cooling module of the Drive Enclosure. One power cooling module is connected to one PDU and the other power cooling module is connected to the other PDU.