Note: To replace a power supply, you can access the faulted power supply from the back of the Replication Engine module. To access the power supply located in the bottom slot (PS-1), the CMA clip must be disconnected to enable the power supply to clear the support arm.
Note: Replacing the power supply does not require you to slide the Replication Engine into the extended rack position and can be performed while the Replication Engine is in the rack position.
- Remove the power supply by grasping the power supply handle and pushing the power supply latch to the left.
Figure 1: Replication Engine power supply latch

- Legend
1 Power supply handle |
3 Power supply |
2 Power supply latch |
4 Replication Engine back |
Figure 2: Remove power supply
- Legend
1 Power supply |
2 Power supply compartment |
3 Replication Engine |
- If both power supplies must be removed, label the power supplies with the slot numbers from which they are removed.
Note: Removing both power supplies will result in the immediate powering off of the Replication Engine. Do not pull both power supplies from an active and running Replication Engine.
Note: The power supplies must be reinstalled into the same slots from which they were removed.
- Pull the power supply out of the chassis and place it on an antistatic mat.