This chapter provides information about the CISCO Switch metrics.
For each metric, it provides the following information:
Description
Metric table
The metric table can include some or all of the following: target version, default collection frequency, default warning threshold, default critical threshold, and alert text.
The Cisco Switch plug-in enables Enterprise Manager Cloud Control to monitor Cisco Switch targets. This plug-in is used to monitor the Cisco switch's CPU, memory, temperature, network interfaces, system information, fan, and power supply metrics. Each Cisco switch will have a plug-in instance added to its agent.
This metric category contains the CPU usage metrics.
This metric displays the average CPU usage over the last 5 minutes, in percent.
The following table shows how often the metric's value is collected and compared against the default thresholds.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 20 | 40 | - |
Data Source
The data is collected using simple network management protocol (SNMP).
User Action
No user action is required.
This metric shows the average CPU usage over the last minute, in percent.
The following table shows how often the metric's value is collected and compared against the default thresholds.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 1 Minute | 20 | 40 | - |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the CPU usage at last metric collection, in percent.
The following table shows how often the metric's value is collected and compared against the default thresholds.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 20 | 40 | - |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric category contains the fan metrics.
This metric shows the status indicator for the switch fan. 1 indicates Normal, 2 Warning, 3 Critical, 4 Shutdown, 5 Not Present, and 6 Not Functioning.
The following table shows how often the metric's value is collected and compared against the default thresholds.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 20 | 3 | State of the fan %KeyValue% is either warning or critical. Current state code is %fanState%. (state code values are mapped as 1=normal,2=warning,3=critical,4=shutdown,5=notPresent,6=notFunctioning) |
Data Source
The data is collected using SNMP push.
User Action
No user action is required.
This metric category contains the memory metrics.
This metric shows the amount of the switch's memory in use, in percent.
The following table shows how often the metric's value is collected and compared against the default thresholds.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | Not Defined | - |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric category contains the network interface metrics.
This metric shows the Admin status for the switch.
The following table shows how often the metric's value is collected and compared against the default thresholds.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | Not Defined | Network Interface %Name% (%Alias%) AdminStatus is %AdminStatus%. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the inbound packets discarded, in percent. The following table shows how often the metric's value is collected and compared against the default thresholds.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 1 | 3 | Percentage of Inbound Packets discarded at Network Interface %Name% are %PercentDiscardsIn%%%. It has crossed warning (%warning_threshold%%%) or critical (%critical_threshold%%%) threshold. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the inbound packet errors, in percent.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 1 | 3 | Percentage of Inbound Packet Errors at Network Interface %Name% are %PercentErrorsIn%%%. It has crossed warning (%warning_threshold%%%) or critical (%critical_threshold%%%) threshold. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the incoming bandwidth in use, in percent.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 80 | 90 | Network Interface %Name% has used %PercentBandwidthUsedIncoming%%% of its bandwidth. It has crossed warning (%warning_threshold%%%) or critical (%critical_threshold%%%) threshold. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the incoming traffic, measured in Kb/s.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | Not Defined | Incoming Traffic rate for network interface %Name% is %NetworkRecdRate%Kilobits/sec. It has crossed warning (%warning_threshold%%%) or critical (%critical_threshold%%%) threshold. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the status of switch interface.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | Failed | Network Interface %Name% (%Alias%) AdminStatus is %AdminStatus%. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the OperStatus of switch.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | Not Defined | Network Interface %Name% (%Alias%) OperStatus is %OperStatus%. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the outbound packets discarded, in percent.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 1 | 3 | Percentage of Outbound Packets discarded at Network Interface %Name% are %PercentDiscardsOut%%%. It has crossed warning (%warning_threshold%%%) or critical (%critical_threshold%%%) threshold. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the outbound packet errors, in percent.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 1 | 3 | Percentage of Outbound Packet Errors at Network Interface %Name% are %PercentErrorsOut%%%. It has crossed warning (%warning_threshold%%%) or critical (%critical_threshold%%%) threshold. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the outbound bandwidth in use, in percent.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | Not Defined | Network Interface %Name% (%Alias%) AdminStatus is %AdminStatus%. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the outbound traffic, measured in Kb/s.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | Not Defined | Outgoing Traffic rate for network interface %Name% is %NetworkSentRate%Kilobits/sec It has crossed warning (%warning_threshold%%%) or critical (%critical_threshold%%%) threshold. |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric category contains the power supply metrics.
This metric shows the status indicator for switch's power supply. 1 indicates Good, 2 indicates Bad, 3 indicates Down.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | Not Defined | 3 | State of the power supply %KeyValue% is either warning or critical. Current state code is %powerSupplyState%. (state code values are mapped as 1=normal,2=warning,3=critical,4=shutdown,5=notPresent,6=notFunctioning). |
Data Source
The data is collected using SNMP push.
User Action
No user action is required.
This is the switch ping time, measured in ms.
The following table shows how often the metric's value is collected.
Target Version | Collection Frequency |
---|---|
All Versions | Every 5 Minutes |
Data Source
The data is collected using SNMP push.
User Action
No user action is required.
This section contains the system information metrics.
This metric shows the contact person for the switch and method of contacting them.
The following table shows how often the metric's value is collected.
Target Version | Collection Frequency |
---|---|
All Versions | Every 5 Minutes |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the host name of the switch.
The following table shows how often the metric's value is collected.
Target Version | Collection Frequency |
---|---|
All Versions | Every 5 Minutes |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the physical location of the switch.
The following table shows how often the metric's value is collected.
Target Version | Collection Frequency |
---|---|
All Versions | Every 5 Minutes |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric shows the number of days since switch has been down.
The following table shows how often the metric's value is collected.
Target Version | Collection Frequency |
---|---|
All Versions | Every 5 Minutes |
Data Source
The data is collected using SNMP.
User Action
No user action is required.
This metric category contains the temperature metrics.
This metric shows the switch's temperature status.
The following table shows how often the metric's value is collected.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | warning | critical | State of the Temperature for %KeyValue% is either warning or critical. Current state is %TemperatureState% (state code values are mapped as 1=normal,2=warning,3=critical,4=shutdown,5=notPresent,6=notFunctioning) and the current temperature status value is %TemperatureStatusValue% Celsius. |
Data Source
The data is collected using both SNMP poll and push.
User Action
No user action is required.
This metric shows the temperature of the switch in degrees celsius.
Target Version | Evaluation and Collection Frequency | Default Warning Threshold | Default Critical Threshold | Alert Text |
---|---|---|---|---|
12c | Every 5 Minutes | 56 | 66 | - |
Data Source
The data is collected using both SNMP poll and push.
User Action
No user action is required.