The following tables provide information on the hardware specifications and the power characteristics of the Pilot, Controller, and Drive Enclosures.
| Attribute | Value | 
|---|---|
| Height | 1.68 in (4.26 cm) | 
| Width | Server chassis (not including ears): 17.19 in (43.65 cm) Server chassis (with bezel): 18.9 in (48.24 cm) | 
| Depth (not including power supply handles) | 29.0 in (73.7 cm) | 
| Weight | 40 lb (18.1437 kg): Weight of one Pilot. | 
| Attribute | Value | 
|---|---|
| Height | 3.45 in (8.76 cm) | 
| Width | 17.52 in (44.55 cm) | 
| Depth | 20.25 in (51.435 cm) | 
| Weight | 41 lb (18.59 kg) | 
| Attribute | Value | 
|---|---|
| Height | 3.46 in (8.79 cm); 2U | 
| Weight (with drives) | 55 lb (24.9 kg) | 
| Width | Width across mounting flange: 19 in (48.26 cm) Width across body of enclosure: 17.44 in (44.29 cm) | 
| Depth | 24.8 in (62.99 cm) | 
| Attribute | Value | 
|---|---|
| Height | 6.92 in (17.57 cm); 4U | 
| Weight (with drives) | 110 lb (49.89 kg) | 
| Width | Width across mounting flange: 19 in (48.26 cm) Width across body of enclosure: 17.44 in (44.29 cm) | 
| Depth | 24.8 in (62.99 cm) | 
| Power characteristic | Value | 
|---|---|
| Frequency | 50–60Hz | 
| AC voltage | 100–240V | 
| Maximum power consumption for both nodes | 314 VA | 
| Current draw for both nodes | 1.42A, 208V | 
| Maximum heat dissipation | 1102 BTU/hr | 
| AC receptacle type | IEC 60320 C14 inlet | 
| Power characteristic | Value | 
|---|---|
| Frequency (nominal) | 50–60 Hz (47–63 Hz range) | 
| Voltage (nominal) | 100 to 127/200 to 240 Volts AC | 
| Input current (maximum) for both nodes | 13.6 A at 100–120 Volts AC (approximately) 8 A at 200–240 Volts AC (approximately) | 
| Maximum power consumption for both nodes | 874 VA (power at maximum FS1 Controller configuration) | 
| Maximum heat dissipation | 2830 BTU/hr | 
| AC receptacle type | IEC 60320 C14 inlet | 
| Power characteristic | Value | 
|---|---|
| Maximum output power | Maximum power consumption depends on the type of Drive Enclosure (DE2-24P or DE2-24C), its size (2U/4U), and configuration. 
 | 
| Frequency | 50–60 Hz | 
| Voltage range | 100–240 Volts AC rated | 
| Maximum range selection | 47–63 Hz | 
| Maximum inrush current | 20A | 
| Power factor correction | 95% or less at nominal input voltage | 
| Harmonics | Meets EN61000-3-2 | 
| Operating temperature | 5° –40° Celsius (41° —104° Fahrenheit) |