10 SNMP Events Reference

This chapter lists the various types of SNMP events that Oracle Communications Evolved Communications Application Server (OCECAS) generates. The value in the SNMP Event column is the name that has been assigned to the unique OID number. The content of the other columns is described by the column name.

Action SNMP Events

Table 10-1 lists the SNMP events generated by the OCECAS action subsystem on the runtime nodes. The runtime nodes are the nodes dedicated to the testing, staging, and production environments.

The SNMP action events are generated mainly for general session processing for all supported session protocols such as SIP, DIAMETER, SOAP and REST.

Table 10-1 Action SNMP Events

SNMP Event Text Cause & Action Event Name OID Postfix

SAS.-236841626

Session in state: {} so cannot send immediate response: {} ({})

Internal inconsistency. Report software fault.

actionInvalidState

.6.1.1.1.1

SAS.1358467794

Failed to find SIP session so cannot send SDP

Internal inconsistency. Report software fault.

actionNoSipSession

.6.1.1.1.2

SAS.1774975313

UAS Session in TERMINATED state so cannot send SDP

Internal inconsistency. Report software fault.

actionUasSessionTerminated

.6.1.1.1.3

SAS.124500320

Invalid SIP session and/or endpoint state

Internal inconsistency. Report software fault.

actionInvalidSessionEndpoint

.6.1.1.1.4

SAS.-783315185

B2B Session in TERMINATED state so cannot send SDP

Internal inconsistency. Report software fault

actionB2bSessionTerminated

.6.1.1.1.5

SAW.807247288

Web service bean failed to send request

Problem sending web request. Check logs and network.

actionWebserviceSendFailed

.6.1.1.2.1

SAW.-2003283391

Web service bean failed to send request

Problem sending web request. Check logs and network

actionWebserviceSendFailed

.6.1.1.2.1

SAW.438621975

SOAP action failed to find SOAP transaction in Registry

Internal inconsistency. Report software fault.

actionWebserviceSoapTxError

.6.1.1.2.2

SAW.-305625600

REST action failed to find REST transaction in Registry

Internal inconsistency. Report software fault.

actionWebserviceRestTxError

.6.1.1.2.3


Charging SNMP Events

Table 10-2 lists the SNMP events generated by the OCECAS charging subsystem on the runtime nodes.

Table 10-2 Charging SNMP Events

SNMP Event Text Cause & Action Event Name OID Postfix

SC.461019824

Cannot send {} CCR because there is no RoSession established

Internal inconsistency. Check charging activities in control flow so report software fault

chargingRequestFailed

.6.1.7.1.1

SC.-610384092

OfflineCharging service: received invalid transaction

Internal inconsistency. Report software fault

chargingRequestFailed

.6.1.7.2.2

SC.1438229309

Could not send CCR: {}

Problem sending charging request. Check logs and network

chargingRequestFailed

.6.1.7.1.1

SC.1959791603

Cannot send {} because RoSession {} is already in progress

Internal inconsistency. Check charging activities in control flow so report software fault

chargingRequestFailed

.6.1.7.1.1

SC.-1759787268

Invalid ACR built from template: {}

A charging template was configured incorrectly. Retract the change set or fix charging template in a new change set

chargingTemplateInvalid

.6.1.7.2.3

SC.-1954822780

Failed to lookup off-line charging service '{}'

Invalid charging service configuration. Configure the charging service correctly.

chargingServiceError

.6.1.7.2.4

SC.-510513429

Cannot send {} ACR because RfSession {} is in terminated state

Internal inconsistency. Check charging activities in control flow so report software fault.

chargingRequestFailed

.6.1.7.2.1

SC.-1378210684

OnlineCharging service: received invalid transaction

Internal inconsistency. Report software fault

chargingRequestFailed

.6.1.7.1.2

SC.1545207092

Cannot send {} CCR because RoSession {} is in terminated state

Internal inconsistency. Check charging activities in control flow so report software fault.

chargingRequestFailed

.6.1.7.1.1

SC.-2106093557

Could not send ACR: {}

Problem sending charging request. Check logs and network

chargingRequestFailed

.6.1.7.2.1

SC.-449017300

Cannot send {} because RfSession {} is already in progress

Internal inconsistency. Check charging activities in control flow so report software fault

chargingRequestFailed

.6.1.7.2.1

SC.103795138

Could not get diameter node from com.bea.wcp.diameter.Node attribute

Invalid diameter configuration. Check that a diameter network-access-point is defined

chargingDiameterError

.6.1.7.3.1

SC.1191760828

Failed to populate charging template: {}

A charging template was configured incorrectly. Retract the change set or fix charging template in a new change set

chargingTemplateError

.6.1.7.3.2

SC.1477636007

Cannot send {} ACR because there is no RfSession established

Internal inconsistency. Check charging activities in control flow so report software fault.

chargingRequestFailed

.6.1.7.2.1

SC.1932756270

Invalid CCR built from template: {}

A charging template was configured incorrectly. Retract the change set or fix charging template in a new change set

chargingTemplateInvalid

.6.1.7.1.3

SC.1873110642

Could not get diameter node from com.bea.wcp.diameter.Node attribute

Invalid diameter configuration. Check that a Diameter network-access-point is defined

chargingDiameterError

.6.1.7.3.1

SC.-284808798

Could not create an Online charging application

Invalid diameter configuration. Check Diameter configuration.

chargingDiameterError

.6.1.7.3.1

SC.-632290436

Failed to lookup on-line charging service '{}'

Invalid charging service configuration. Configure the charging service correctly.

chargingServiceError

.6.1.7.1.4

SC.-1480789177

Could not send Diameter message: {}

Problem sending charging request. Check logs and network

chargingDiameterError

.6.1.7.3.1

SC.-1333890964

Failed to populate charging template: {}

A charging template was configured incorrectly. Retract the change set or fix charging template in a new change set.

chargingTemplateError

.6.1.7.3.2

SC.288526327

Could not send Diameter message: {}

Problem sending charging request. Check logs and network.

chargingDiameterError

.6.1.7.3.1


Chassis SNMP Events

Table 10-3 lists the SNMP events generated by the OCECAS chassis subsystem on the runtime nodes. These SNMP events are generated mainly for general session processing for all supported session protocols such as SIP, DIAMETER, SOAP and REST.

Table 10-3 Chassis SNMP Events

SNMP Event Text Cause & Action Event Name OID Postfix

SC.2119666489

Invalid engine state ID {} in response

Internal inconsistency. Report software fault

chassisInvalidEngineState

.6.1.5.1

SE.-259869001

Invalid configuration in control flow {} for activity {} and message: {}

A control flow activity was configured incorrectly. Retract the change set or fix control flow in a new change set.

engineControlFlowInvalid

.6.1.6.1

SC.-1647253768

Failed to load control flow key for protocol: '{}' and method: '{}'

There is no application trigger configured for the specified protocol and method. Ensure that the database contains a valid application trigger entry.

chassisLoadControlFlowFailed

.6.1.5.2


Media SNMP Events

Table 10-4 lists the SNMP events generated by the OCECAS media subsystem on the runtime nodes.

Table 10-4 Media SNMP Events

SNMP Event Text Cause & Action Event Name OID Postfix

SM.-1340286052

Failed to initialise MediaParticipant: {}

Can't process media transaction. Check the media server is available.

mediaParticipantInitFailed

.6.1.4.1

SM.917837316

Invalid media server configuration: {}

Can't process media transaction. Configure the media server correctly

mediaServerConfigInvalid

.6.1.4.2


User Profile SNMP Events

Table 10-5 lists the SNMP events generated by the OCECAS UDR subsystem on the runtime nodes.

Table 10-5 User Profile SNMP Events

SNMP Event Text Cause & Action Event Name OID Postfix

SA.73957577

Failed to update UDR

UpdateProfile failed. Check log for more information.

activityUpdateProfileFailed

.6.1.3.1

SU.-852056064

handleProfileNotification: session has null transaction

Internal inconsistency. Report software fault.

userProfileNotificationFailed

.6.1.2.5

SU.-1967106361

Failed to create UDR update request

Internal inconsistency. Report software fault.

userProfileUpdateRequestFailed

.6.1.2.3

SU.-756848176

Failed to send UDR read request: {}

Problem sending UDR request. Check logs and network.

userProfileReadRequestFailed

.6.1.2.2

SU.1546249155

Failed to send UDR update request: {}

Problem sending UDR request. Check logs and network

userProfileUpdateRequestFailed

.6.1.2.4

SU.-561858002

UDR handler '{}' returned null service

Invalid UDR service configuration. Configure the UDR service correctly

userProfileServiceHandlerError

.6.1.2.6

SU.-1400801029

Failed to create UDR request builder

Internal inconsistency. Report software fault

userProfileRequestError

.6.1.2.7

SU.-208267932

handleUpdateResponse: called with null response

Internal inconsistency. Report software fault

userProfileUpdateResponseFailed

.6.1.2.4

SU.837283091

handleReadResponse: session has null transaction

Internal inconsistency. Report software fault.

userProfileReadResponseFailed

.6.1.2.2

SU.1109342659

handleUpdateResponse: response has null session

Internal inconsistency. Report software fault.

userProfileUpdateResponseFailed

.6.1.2.4

SU.-29369338

handleUpdateResponse: session has null transaction

Internal inconsistency. Report software fault

userProfileUpdateResponseFailed

.6.1.2.4

SU.2053540822

handleReadResponse: response has null session

Internal inconsistency. Report software fault.

userProfileReadResponseFailed

.6.1.2.2

SU.1699875721

handleReadResponse: transaction has null app session id

Internal inconsistency. Report software fault.

userProfileReadResponseFailed

.6.1.2.2

SU.1517428308

Failed to create UDR read request

Internal inconsistency. Report software fault.

userProfileReadRequestFailed

.6.1.2.1

SU.1670068532

handleProfileNotification: event has null session

Internal inconsistency. Report software fault.

userProfileNotificationFailed

.6.1.2.5

SU.735930231

handleReadResponse: called with null response

Internal inconsistency. Report software fault.

userProfileReadResponseFailed

.6.1.2.2

SU.397693795

handleProfileNotification: called with null event

Internal inconsistency. Report software fault.

userProfileNotificationFailed

.6.1.2.5


Web Request SNMP Events

Table 10-6 lists the SNMP events generated by the OCECAS web service subsystem on the runtime nodes.

Table 10-6 Web Request SNMP Events

SNMP Event Text Cause & Action Event Name OID

SW.2044210026

Failed to find the transaction.

Internal inconsistency. Report software fault.

webRequestTransactionError

.6.1.8.1

SW.2035879783

Unable to Construct REST client. REST client actions will be unavailable.

Problem sending web request. Check logs and network.

webRequestClientError

.6.1.8.2

SW.609982854

Unable to perform REST client action because there is no REST client.

Problem sending web request. Check logs and network

webRequestClientError

.6.1.8.2

SW.153863372

Web session: received invalid transaction

Internal inconsistency. Report software fault

webRequestTransactionError

.6.1.8.1

SW.1380968501

Web session: received invalid transaction

Internal inconsistency. Report software fault.

webRequestTransactionError

.6.1.8.1

SW.-335797324

Received REST Error response: {}

Web request failed. Check logs and network.

webRequestClientError

.6.1.8.2

SW.-110818330

Invalid WS response context so ignoring JAX-WS response.

Internal inconsistency. Report software fault

webRequestClientError

.6.1.8.2

SW.-650174813

Web handler '{}' returned null service

Invalid web service configuration. Configure the web service correctly.

webRequestServiceError

.6.1.8.3

SW.-27831726

Web handler '{}' returned null service2

Invalid web service configuration. Configure the web service correctly.

webRequestServiceError

.6.1.8.3

SW.-1023652141

Failed to find the transaction.

Internal inconsistency. Report software fault

webRequestTransactionError

.6.1.8.1