SNI keyboard

The program description deals with the following:

Remarks on program function

The data for a device of type SNI keyboard can be updated, i.e. programmed, changed or cleared, with this program. Data which already exists can also be displayed for information.

The interface and link to a processing unit should be defined and the device-specific operating mode set.

Note:
When using this keyboard under LINUX/UNIX, the "X SERVER" option must be set for the associated process unit
of the terminal.


Remarks on data fields

The following description deals with all available options for update of this basic data.

As with nearly all other programs the following also applies here:


Debug

Field with firmly defined selection options

Select one of the offered debug levels by clicking on the fiekd and with a second click to confirm the option required.

The system offers the following debug levels:

Note:
Only select a value higher than "0" for the debug level if a protocol for the communication of the keyboard is required for error analysis. Information can be found in file "errlog" in directory work of the appropriate system unit.


Keyboard no.

Entry range permitted: numeric 1 - 9999

Enter a keyboard ID no. for the keyboard which is to be linked for use in the sales program. If the number is not known, the data record can be selected with the search function.


Central lock

Switch active: A central lock can be connected to this keyboard

Switch deactivated: No central lock is connected to this keyboard


Pos 0

Default = 0

Enter the value for the lock position. This value is used, amongst other things, in program Terminal profile to check the various POS functions.


Pos 1

Default = 1

Enter the value for the lock position. This value is used, amongst other things, in program Terminal profile to check the various POS functions.


Pos 2

Default = 2

Enter the value for the lock position. This value is used, amongst other things, in program Terminal profile to check the various POS functions.


Pos X

Default = 3

Enter the value for the lock position. This value is used, amongst other things, in program Terminal profile to check the various POS functions.


Pos Z

Default = 4

Enter the value for the lock position. This value is used, amongst other things, in program Terminal profile to check the various POS functions.


Pos T

Default = -1

Enter the value for the lock position. This value is used, amongst other things, in program Terminal profile to check the various POS functions.


Pos P

Default = 5

Enter the value for the lock position. This value is used, amongst other things, in program Terminal profile to check the various POS functions.


Index


MICROS Retail Deutschland GmbH
Salzufer 8
D-10587 Berlin