Power Management State Changes

The following table describes the scenarios in which the power management state changes for the Workstation 625/655.

Table 5-1 Power Management State Changes

Starting State Event Resulting State

Unplugged

AC power is connected to a wall outlet and the last recorded power state was not the ON state.

NOPOWER

NOPOWER

The operator presses the power button for less than 1 second.

ON

NOPOWER

The operator presses the power button for more than 4 seconds.

ON

NOPOWER

A server application sends a Wake On LAN command.

ON

NOPOWER

AC power fails and then is restored.

NOPOWER*

ON

The operator presses the power button for less than 1 second.

NOPOWER**

ON

The application shuts down the workstation.

NOPOWER

ON

The Client Application Loader sends a Restart command.

NOPOWER and then ON

ON

AC power fails and then is restored.

ON*

*Based on the default BIOS power settings.

**Microsoft Windows: Pressing the power button begins a graceful shutdown. This behavior is based on the Windows power button management setting. Oracle Linux for MICROS: Pressing the power button initiates a graceful shutdown, but shutdown may take up to 10 seconds to complete.