If your environment uses concept databases, perform the following steps to upgrade:
Make sure:
The concept database files are configured and placed in the correct location.
The HKLM\Software\Micros\Enterprisemanagement\Userdata registry key and the encryption key files, such as concept.dat are configured and functional in the previous version.
Copy EmDbUpdate.mbz3 from \Tools\ to \micros\Database\Data\.
Install RES and upgrade the master database.
Install Enterprise Management.
Launch the MECU, navigate to Concept Setup, right-click the concept, and click Set Available.
Launch Database Manager.