Use the odaadmcli show iraid
command to display details of the internal RAID sub-system.
Syntax
To display details of the internal RAID subsystem:
odaadmcli show iraid [-h]
Parameters
Parameter | Description |
---|---|
|
(Optional) Displays help for using the command. |
Example 9-22 Displaying Details of the Internal RAID Sub-system
To display details of the internal RAID sub-system:
# odaadmcli show iraid NAME CTRL# PRODUCT SERIAL_NO BIOS_VER FW_VER IR_0_0_0 0 LSI MegaRAID 9361-8i SV52756042 6.17.04.2_4.16.08.00_0x06060A IR_0_0_1 0 LSI MegaRAID 9361-8i SV52756042 6.17.04.2_4.16.08.00_0x06060A VDISK_TYPE VDISK_STATE PDISK_MODEL 4.230.40-3739 RAID1 Optl MS4SC2JH2ORA480G 4.230.40-3739 RAID1 Optl MS4SC2JH2ORA480G EID:SLT PDISK_STATE SIZE CV_MODEL CV_STATE CV_TEMP 252:0 Onln 446.102 GB CVPM02 Optimal 25C 252:1 Onln 446.102 GB CVPM02 Optimal 25C