19227 - Received unsolicited ASP-DOWN-ACK
- Event Type:
- SS7
- Description:
- The adjacent server at the specified IP address and port has sent an ASP-DOWN-ACK, but not in response to an ASP-DOWN message from the MP server. Normally this indicates that the far-end of the association is being taken down for maintenance. If the association administrative state is Enabled, the MP server will automatically attempt to bring the association back to ASP-UP. This is done by sending an ASP-UP. The MP server will continue to send ASP-UP until an ASP-UP-ACK is received, the SCTP association comes down, or the association administrative state is changed to Blocked or Disabled.
- Severity:
- Info
- Instance:
- <AssocName>
- HA Score:
- Normal
- Throttle Seconds:
- 30
- OID:
- awpss7ReceivedUnsolicitedAspDownAckNotify
Recovery:
- Verify that the adjacent server on the Signaling Gateway is not under maintenance.
- If the problem persists, contact My Oracle Support (MOS).