1317 - ICNP: Response PC unknown

This UIM occurs when the OPC of the IAM for processing is not known..

Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 33.2.0
0140.1317 CARD 1201 INFO ICNP:  Response PC unknown

Alarm Level: No alarm condition. The message is informational only.

Recovery

If this UIM appears, take these actions:
  • Check the point code using the rtrv-dstn command.