19800 - Communication Agent Connection Down

Alarm Group:
CAF
Description:
This alarm indicates that a Communication Agent is unable to establish transport connections with one or more other server, and this may indicate applications on the local server are unable to communicate with all of their peers. Generally this alarm is generated when a server or the IP network is undergoing maintenance or when a connection has been manually disabled.
Severity:
Major
Instance:
N/A
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
cAFConnectionDownNotify

Recovery:

  1. Navigate to Main Menu > Alarms & Events > View History to find additional information about the alarm.

    The information can be found by locating the row with a sequence number that matches the active alarm sequence number and viewing the Additional Info column.

  2. Check the event history logs by navigating to Main Menu > Alarms & Events > View History for additional Communication Agent events or alarms from this MP server.
  3. Navigate to Main Menu > Communication Agent > Maintenance > Connection Status to determine which connections on the server have abnormal status.
  4. If the connection is manually disabled, then no further action is necessary.
  5. Verify the remote server is not under maintenance.
  6. Verify IP network connectivity exists between the two connection end-points.
  7. Verify the connection’s local IP address and port number are configured on remote node.
  8. Verify the Application Process using Communication Agent plug-in is running on both ends.
  9. Verify the connection’s remote IP address and port correctly identify remote’s listening port.
  10. It is recommended to contact unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0 for assistance.