Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

13354 - UDRBE Provisioning Task Message Queue Utilization

Alarm Type:
UDR
Description:
The UDRBE application’s provisioning task message queue is approaching its maximum capacity. This alarm should not occur when no other congestion alarms are asserted. The alarm severity depends upon the amount of the UDRBE provisioning task message queue being used:
  • Minor when utilization exceeds 60%.
  • Major when utilization exceeds 80%.
  • Critical when utilization exceeds 95%.
Severity:
Major (Minor, Critical)
Instance:
N/A
HA Score:
Normal
Auto Clear Seconds:
0
OID:
UdrbeProvisioningTaskMessageQueueUtilization

Recovery:

  1. Determine whether the traffic rate of the system is too high. If yes, reduce traffic rate to clear alarm. The alarm clears when utilization falls below these thresholds:
    • <= 50% (clears Minor alarm)
    • <= 70% (clears Major alarm)
    • <= 90% (clears Critical alarm)
  2. If the problem persists, contact My Oracle Support.