RxAsnInvalidM3ua

Measurement ID
9143
Measurement Group
Association Exception
Measurement Type
Simple
Measurement Dimension
Arrayed (per association)
Description
The number invalid M3UA messages received on this association. An invalid M3UA message is a message that violates the M3UA protocol.
Collection Interval
30 min
Peg Condition
This measurement is incremented by one each time an M3UA message is received on the association that is invalid due to any syntactic or semantic reason.
Measurement Scope
NE, Server

Recovery

  1. This measurement should have a zero value. In case of a non-zero value in this measurement, review the event history from the GUI main menu under Alarms & Events > View History, looking for Event 19231.
  2. Event 19231 provides details about the reason for rejecting the M3UA message. If the error reason indicates a problem with routing context, verify that the routing context used for the association specified in Event 19231 is configured to match between the ASP and the SG.
  3. It is recommended to contact My Oracle Support for assistance if needed.