CAStackQueueFul

Measurement ID
9829
Measurement Group
ComAgent Exception
Measurement Type
Simple
Measurement Dimension
Arrayed
Description
StackEvents discarded due to ComAgent task queue full condition.
Collection Interval
30 min
Peg Condition
For each User Data egress StackEvent that is discarded by ComAgent Stack, due to failure in attempting to put the messages in ComAgent Egress Task Queue.
Measurement Scope
NE, Server

Recovery

  1. If both the peak and average measurement for multiple MPs within a Network Element are consistently near the recommended maximum engineered capacity of an MP over several collection intervals, then the number of MPs in the Network Element may need to be increased.
  2. If the peak and average for an individual MP is significantly different than other MPs in the same Network Element then an MP-specific hardware, software, or configuration problem may exist.
  3. It is recommended to contact My Oracle Support for assistance.