Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

CAPeakMxFIFOQueueUtil

Measurement ID
9966
Measurement Group
ComAgent Performance
Measurement Type
Max
Measurement Dimension
Arrayed
Description
Maximum percentage of ComAgent MxFIFO Queue Utilization.
Collection Interval
30 min
Peg Condition
The maximum ComAgent connection MxFIFO Queue utilization sample taken during the collection interval.
Measurement Scope
NE, Server

Recovery

  1. This measurement is primarily intended to assist in evaluating any issues with internal StackEvent processing and thread scheduling.

    If both the peak and average measurement for multiple MPs within a Network Element are consistently near the recommended maximum engineered capacity of an MP over several collection intervals, then the queue depth may need to be tuned.

    If the peak and average for an individual MP is significantly different than other MPs in the same Network Element then an MP-specific hardware, software, or configuration problem may exist.

  2. It is recommended to contact My Oracle Support for assistance.