EvSctpAdjPToDwn
- Measurement ID
- 9424
- Measurement Group
- Transport Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed (per Transport)
- Description
- Number of times configured IP Address of an Adjacent Node goes from Available to Unavailable.
- Collection Interval
- 30 min
- Peg Condition
- This measurement shall be incremented by one each time reachability to a configured IP address of an Adjacent Node is lost, indicating a fault in the path to that address was detected. If all is well, the measurement will have a zero value. A non-zero value indicates that a path fault to that address was detected.
- Measurement Scope
- NE, Server
Recovery
- Check the event history log at ; look for event ID 19410. Event ID 19410 provides more details about the actual cause of the failure.
- Verify that the Adjacent Node that represents the far-end of the association is configured with the correct IP address at .
- Verify IP network connectivity between the MP server and the Adjacent Nodes IP address using a ping or traceroute command.