Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

RxLnkM3uaERROR

Measurement ID
9123
Measurement Group
Link Exception
Measurement Type
Simple
Measurement Dimension
Arrayed (per link)
Description
The number of times an M3UA ERROR message was received for the link. M3UA ERROR message are sent to indicate invalid M3UA signaling.
Collection Interval
30 min
Peg Condition
This measurement is incremented by one each time an M3UA ERROR message is received and that ERROR message can be attributed to a specific link (i.e., the ERROR message contains a valid routing context, or no routing context is needed).
Measurement Scope
NE, Server

Recovery

  1. This measurement should have a value of zero. A non-zero value indicates a problem with the M3UA signaling sent by the MP server.
  2. Look for Event ID 19235 from the GUI main menu under Alarms & Events > View History. Event ID 19235 provides information on the reason for the receipt of the ERROR message.
  3. If the ERROR reason in Event ID 19235 indicates a problem with routing context (i.e., error code 0x19), verify that the MP server link set and the SG are configured to agree on the routing context values that each M3UA signaling link uses.
  4. It is recommended to contact My Oracle Support for assistance if needed.