32339 - TPD Max Number Of Running Processes
Error
- Alarm Group:
- PLAT
- Description:
- This alarm indicates that the maximum number of
running processes has reached the major threshold.
- Severity:
- Major
- Instance:
- May include AlarmLocation, AlarmId, AlarmState,
AlarmSeverity, and bindVarNamesValueStr
- HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- tpdMaxPidLimit
- Alarm ID:
- TKSPLATMA40
Recovery:
-
Run syscheck in verbose mode.
-
Execute 'pstree' to see what pids are on the system
and what process created them. Collect the output of command, and review the
output to determine the process responsible for the alarm.
-
It is recommended to contact
unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0 and
provide the system health check output, and pid output.