22075 - Message is not routed to Application

Alarm Group:
DIAM
Description:
ART Rule-X was selected, but message was not routed because DSR Application is disabled or not available.
Severity:
Major
Instance:
<DSR Application Name>
HA Score:
Normal
Auto Clear Seconds:
0
OID:
eagleXgDiameterArtMatchAppUnavailableNotify

Recovery:

  1. Check the Application Status by navigating to Diameter > Maintenance > Applications and Enable the application if the Admin State of the DSR application is Disabled for a particular DA-MP(s) which raised the alarm.
  2. If the Application is Enabled for a particular DA-MP, but the Operational Status is Unavailable or Degraded, then refer to the Operational Reason and rectify it accordingly.
  3. If the problem persists, it is recommended to contact unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0.