Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

10009 - Config and Prov db not yet synchronized

Alarm Group:
REPL
Description:

The configuration and the provisioning databases are not yet synchronized. The 10009 alarm raises when DB re-initialization is attempted but fails. The re-initialization usually happens when transitioning to 'A' state (one of the procmgr state, can get it from pl command). DB re-initialization fails because the remote server is not in the correct state, for example, it is not in OOS state.

This alarm can also be observed during some DSR patch installation after the DB replication is inhibited. As long as this alarm is cleared (NOT stuck) after DB replication is allowed, it is normal behavior and we expect to see alarm 10009 when applying the patch.

Severity:
Critical
Instance:
N/A
HA Score:
Failed
Auto Clear Seconds:
This alarm does not autoclear.
OID:
oAGTCfgProvDbNoSyncNotify

Recovery:

  1. Monitor the replication status by navigating to Status & Manage > Replication GUI.
  2. If alarm persists for more than one hour, it is recommended to contact unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0.