Adding a Provisioning Connection

Use this procedure to define an allowable remote connection. Only servers added through this procedure can remotely connect to the primary provisioning site's NOAMP server and execute commands.

Note:

Connection options must be set prior to configuring connections. For more information about this option, see Provisioning Options.

You can only perform this task when logged into the Active Primary NOAMP.

  1. Select UDR > Configuration > Provisioning Connections.
    The Provisioning Connections page appears.
  2. Click Insert.
    The Provisioning Connections [Insert] page appears.
  3. Enter a system ID in the System ID field. This field is required.
  4. Enter a unique IP address for the provisioning connection in the IP Address field. This field is required.
  5. Perform one of the following:
    • Click OK to save the provisioning connection and return to the Provisioning Connections page.
    • Click Cancel to return to the Provisioning Connections page without saving the changes.
    If OK is clicked and any of the following conditions exist, an error message appears:
    • Any required field is empty; no value was entered or selected
    • The entry in any field is not valid (wrong data type or out of the valid range)
    • The IP Address is not unique; it already exists in the system