A Replacement Units

This appendix lists the replacement units for Oracle Exadata Database Machine and Oracle Exadata Storage Expansion Rack. There are two types of replacement units, FRUs (field replaceable units), and CRUs (customer replaceable units). FRUs are installed by trained Oracle field technicians. CRUs are installed by the customer.

This appendix contains the following topics:

Note:

  • For ease of reading, the name "Oracle Exadata Rack" is used when information refers to both Oracle Exadata Database Machine and Oracle Exadata Storage Expansion Rack.

  • All replacement parts for Oracle Exadata Database Machine in this appendix, except database servers, are applicable to Oracle Exadata Storage Expansion Racks.

See Also:

The component-specific chapter in this book for information about the pre-installation and post-installation steps

A.1 Understanding Repair Categories

Repair categories describe the potential impact of a repair action. Table A-1 describes the categories, and actions.

Table A-1 Oracle Exadata Rack Repair Categories

Category Description Scenario Examples

Hot Swap (HS)

Repair part is hot swappable, and may be replaced without shutting down the host system. Commands may be needed before and after replacement to protect data.

  • Disks

  • Fans

  • Power supplies

Infrastructure Repair (IR)

Repair of connectivity component within Oracle Exadata Rack. No downtime of the rack is required, however, individual components may require downtime.

  • External cables

  • InfiniBand switch

  • Ethernet switch

  • KVM switch/KMM tray

Database Server Offline (DBO)

Repair of the part requires one database server in Oracle Exadata Database Machine be shut down. No downtime of the rack is required, however individual server nodes may require downtime and be taken outside of the cluster temporarily.

If the system is currently running, then it should be shut down gracefully. See "Powering On and Off Oracle Exadata Rack" for additional information.

If monitoring the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Cloud Control Administrator's Guide for additional information.

  • System boards

  • PCIe cards

  • Memory

  • Processors

  • Power distribution units

Exadata Storage Server Offline (EBO)

Repair of the part requires one Exadata Storage Server within Oracle Exadata Rack be shut down. No downtime of the rack is required, however individual server nodes may require downtime and be taken outside of the cluster temporarily. Temporary performance impact due to rebalancing to maintain data redundancy may occur.

If the system is currently running, then it should be shut down gracefully. See "Powering On and Off Oracle Exadata Rack" for additional information.

If monitoring the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Cloud Control Administrator's Guide for additional information.

  • System boards

  • PCIe cards

  • Memory

  • Processors

A.2 Regulatory and Certificate Compliance

Parts used in Oracle Exadata Database Machine and Oracle Exadata Rack comply with the following regulations and certifications:

  • Regulations

    • Safety: UL/CSA 60950-1, EN 60950-1:2006 CB Scheme with all country differences

    • RFI/EMI: EN 55022, EN 61000-3-12

    • Immunity: EN 55024

    • Emissions and Immunity: EN 300 386

  • Certifications

    • North America (NRTL), European Union (EU), International CB Scheme, BSMI (Taiwan), C-Tick (Australia), CCC (PRC), MSIP (Korea), CU EAC (Customs Union), VCCI (Japan)

  • European Union Directives

    • 2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive, 2011/65/EU RoHS Directive, 2012/19/EU WEEE Directive

Note:

In some cases, as applicable, regulatory and certification compliance were obtained at the component level.

A.2.1 Compliance with the European Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Directive

Parts that have the RoHS:Y or RoHS:YL designation are compliant with the European Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Directive, as follows:

  • RoHS:Y compliance is based on present information and belief, this equipment/part number complies with the European Union RoHS Directive, 2002/95/EC, and amending and guidance documents, and does not contain any restricted substances above the homogeneous materials' maximum concentration values, except for selected exemptions allowed by law (excluding the exemption for lead in solders for servers, storage and storage array systems, network infrastructure equipment for switching, signaling, transmission as well as network management for telecommunications).

  • RoHS:YL compliance is based on present information and belief, this equipment/part number complies with the European Union RoHS Directive, 2002/95/EC, and amending and guidance documents, and does not contain any restricted substances above the homogeneous materials' maximum concentration values, except for selected exemptions allowed by law (including the exemption for lead in solders for servers, storage and storage array systems, network infrastructure equipment for switching, signaling, transmission as well as network management for telecommunications).

  • If a part description contained in a parts list does not contain RoHS:Y or RoHS:YL in its description, this indicates that the part is not RoHS compliant or the information necessary to confirm its compliance has yet to be provided by the product team.

A.3 Disk Controller Batteries

The disk controllers in Exadata Storage Servers and database servers have battery-backed write cache to accelerate write performance.

This section applies only to systems that use batteries. Oracle Exadata Database Machine X6 has no batteries. Newer machines have CVPM02 (Cache Vault), which is a super cap and not a battery.

If the battery charge capacity degrades such that the battery can no longer protect the cached data for a power loss of 48 hours or more, then the write cache is disabled and the disk controller switches to write through mode. This results in reduced write performance, but there is no data loss. Exadata Storage Servers generate an alert when battery charge capacity is insufficient or the temperature is high, and when the battery should be replaced.

Battery charge capacity degrades over time, and its life expectancy is inversely proportional to the operating temperature. The worst case life expectancy of the battery in Oracle Exadata Rack is as follows:

Inlet Ambient Temperature Battery Lifetime

< 25 degrees Celsius (77 degrees Fahrenheit)

3 years

< 32 degrees Celsius (89.6 degrees Fahrenheit)

2 years

A.3.1 Monitoring Batteries in the Database Servers

The battery change capacity in the database servers can be monitored using the following command:

# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -a0 | grep "Full Charge" -A5 | sort \
| grep Full -A1

The following is an example of the output from the command:

Full Charge Capacity: 1357 mAh
Max Error: 2 %

Proactive battery replacement should be done on batteries that show capacity less than 800 mAh and have maximum error less than 10%. Immediately replace any battery that has less than 674 mAh or has maximum error more than 10%.

The battery temperature can be monitored using the following command:

/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -a0 | grep BatteryType; \
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -a0 | grep -i temper

The following is an example of the output from the command:

BatteryType: iBBU08
Temperature: 38 C
  Temperature                  : OK
  Over Temperature        : No

If the battery temperature is greater than or equal to 55 degrees Celsius, then determine the cause, and correct the problem.

Note:

Exadata Storage Servers generate an alert when battery charge capacity is insufficient or the temperature is high, and when the battery should be replaced.

A.3.2 Replacing Batteries in Disk Controllers

If the battery charge capacity in the disk controllers falls below the minimum threshold, then Oracle will replace the failed batteries at no extra charge, if the system is covered either by the Oracle Premier Support for Systems or occurs during the warranty period.

For customers with Premier Support for Systems, Oracle attempts to proactively replace the batteries in Oracle Exadata Rack before the end of the estimated lifetime, on a best efforts basis.

A.4 F20 PCIe Energy Storage Modules

Sun Flash Accelerator F20 PCIe cards accelerate performance in Oracle Exadata Rack by caching frequently-accessed Oracle Database data and avoids the need to do physical I/O to the disk in Exadata Storage Server. Write operations to the flash cards are temporarily staged in volatile local DRAM memory on the card to speed write operations. The data in the DRAM is protected by an Energy Storage Module (ESM) which provides enough electrical power, in the event of a power failure, to move the data in the DRAM to the local flash.

The flash modules used in Oracle Exadata X3 systems have an expected endurance of 10 years or more, even in write intensive applications. Flash endurance is determined primarily by the total data written to flash across many years, as well as the type of data written. No application runs at maximum flash write IOPS for every second of every day for years. Applications also do many reads and have periods of high and low activity, such as day versus night, quarter close, end of a trading day, and so on. A very highly write intensive application might average 25 percent of the maximum flash write IOPS when measured over many months. Each Exadata X3 storage server has a total flash write endurance of over 50 PB for typical database data. In a full rack, if the application writes an average of 250,000 8K flash IOPS (25 percent of maximum writes) for 10 years, then it will write a total of 41 PB of data to each cell. This is less than the 50 PB per cell endurance.

If the ESM does not have sufficient charge, then the F20 PCIe card operates in fail-safe write-through mode, bypassing the DRAM memory and writing all data directly to flash. This results in reduced write performance, but there is no data loss. Exadata Storage Server generates an alert when the ESM capacity is insufficient, and the ESM should be replaced.

The charge capacity of the ESM degrades over time, and its life expectancy is inversely proportional to the operating temperature. The worst case life expectancy of the ESM in Oracle Exadata Rack is as follows:

Type of Exadata Storage Server Lifetime

Exadata Storage Server with Sun Fire X4275 Servers

3 years

Exadata Storage Server with Sun Fire X4270 M2 Servers

4 years

A.4.1 Replacing Flash ESM

If the charge capacity in the F20 PCIe ESM falls below the minimum threshold, then Oracle will replace the failed ESM modules at no extra charge, if the system is covered either by the Oracle Premier Support for Systems or occurs during the warranty period.

For customers with Premier Support for Systems, Oracle attempts to proactively replace the F20 PCIe ESM in the Oracle Exadata Rack before the end of the estimated lifetime, on a best efforts basis.

A.5 LED Status Descriptions

This section describes the LEDs in Oracle Exadata Rack, and contains the following topics:

A.5.1 Oracle Server X5-2 and later Oracle Database Server LEDs

The following table describes the color codes of the LEDs on Oracle Server X5-2 and later Oracle Database Servers.

Table A-2 Oracle Server X5-2 and later Oracle Database Server LED Status Descriptions

Component LED Status

Oracle Server X5-2 and later Oracle Database Server fan module

  • Fan Status LED is off: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Oracle Server X5-2 and later Oracle Database Server power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Oracle Server X5-2 and later Oracle Database Server servers

  • OK to Remove LED is blue: The storage drive can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The system is running but the storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

The following table describes the disk status based on the LEDs.

Table A-3 Disk Status of Oracle Server X5-2 and later Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

  • Off (until Oracle ASM rebalance and flash cache flush complete)

  • On (when it is safe to remove the disk)

On

On

Note:

The OK to Remove LED is initially off when a disk enters predictive failure status. After both (if applicable) the Oracle ASM rebalance and flash cache flush operations complete, then it’s safe to replace the disk without compromising redundancy, and the OK to Remove LED is turned on.

A.5.2 Sun Server X4-2 Oracle Database Server LEDs

Table A-4 describes the color codes of the LEDs on Sun Server X4-2 Oracle Database Servers.

Table A-4 Sun Fire X4170 M2 Oracle Database Server LED Status Descriptions

Component LED Status

Sun Server X4-2 Oracle Database Server fan module

  • Fan Status LED is green: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Sun Server X4-2 Oracle Database Server power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Sun Server X4-2 Oracle Database Server servers

  • OK to Remove LED is blue: The storage drive can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The system is running but the storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-5 describes the disk status based on the LEDs.

Table A-5 Disk Status of Sun Server X4-2 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.3 Sun Server X3-2 Oracle Database Server LEDs

Table A-6 describes the color codes of the LEDs on Sun Server X3-2 Oracle Database Servers.

Table A-6 Sun Server X3-2 Oracle Database Server LED Status Descriptions

Component LED Status

Sun Server X3-2 Oracle Database Server fan module

  • Fan Status LED is green: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Sun Server X3-2 Oracle Database Server power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Sun Server X3-2 Oracle Database Server servers

  • OK to Remove LED is blue: The storage drive can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The system is running but the storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-7 describes the disk status based on the LEDs.

Table A-7 Disk Status of Sun Server X3-2 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.4 Sun Fire X4170 M2 Oracle Database Server LEDs

Table A-8 describes the color codes of the LEDs on Sun Fire X4170 M2 Oracle Database Servers.

Table A-8 Sun Fire X4170 M2 Oracle Database Server LED Status Descriptions

Component LED Status

Sun Fire X4170 M2 Oracle Database Server fan module

  • Fan Status LED is green: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Sun Fire X4170 M2 Oracle Database Server power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Sun Fire X4170 M2 Oracle Database Server servers

  • OK to Remove LED is blue: The storage drive can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The system is running but the storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-9 describes the disk status based on the LEDs.

Table A-9 Disk Status of Sun Fire X4170 M2 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.5 Sun Fire X4170 Oracle Database Server LEDs

Table A-10 describes the color codes of the LEDs on Sun Fire X4170 Oracle Database Servers.

Table A-10 Sun Fire X4170 Oracle Database Server LED Status Descriptions

Component LED Status

Sun Fire X4170 Oracle Database Server fan module

  • Power/OK LED is green: The system is powered on and the fan module is functioning correctly.

  • Service Action Required LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Sun Fire X4170 Oracle Database Server power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Sun Fire X4170 Oracle Database Server servers

  • OK to Remove LED is blue: A storage drive can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The system is running and the storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-11 describes the disk status based on the LEDs.

Table A-11 Disk Status of Sun Fire X4170 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

Flashing

Flashing

On

OK to Remove (Blue)

Off

Flashing

Flashing

A.5.6 Oracle Server X5-8 and X6-8 Oracle Database Server LEDs

Table A-12 describes the color codes of the LEDs on Oracle Server X5-8 and X6-8 Oracle Database Server.

Table A-12 Oracle Server X5-8 and X6-8 Oracle Database Server LED Status Descriptions

Component LED Status

Oracle Server X5-8 or X6-8 Oracle Database Server Back Panel PCIe Card Carriers (DPCC)

  • ATTN Button LED: Press to remove and to add the PCIe to the operating system.

  • Service Action Required (fault) LED is amber: There is a fault condition.

  • OK LED is green: PCIe is ready, and in use by the operating system.

Oracle Server X5-8 or X6-8 Oracle Database Server hard drives

  • Hot Swap LED is blue: The hard drive can safely be removed.

  • Fault is amber: The hard drive is faulty.

  • Activity is green: Flashing indicates drive activity, and standby.

Oracle Server X5-8 or X6-8 Oracle Database Server power supply

  • PSU Fault LED is amber: The power supply has a fault condition.

  • PSU OK LED is green: The power supply is on.

  • AC LED is green: AC is connected to the power supply.

Oracle Server X5-8 or X6-8 Oracle Database Server service processor (SP) modules

  • 10/1000/1000Base-T Ethernet LED (left): Green indicates link is established at 1 gigabit. Amber and on indicates link is established at 100 megabits. Amber and off indicates link is established at 10 megabits.

  • 10/1000/1000Base-T Ethernet LED (bottom) is green: There is activity on the link.

  • Chassis Service Action Required (fault) LED is amber: There is a fault condition.

  • Chassis Power OK LED: Green indicates full power mode. It flashes quickly during SP boot when AC power cords are connected to the server. It flashes slowly in standby power mode.

  • Chassis Over-temperature LED is amber: The internal server temperature exceeds the upper threshold.

  • SP module OK LED: It is green and on when SP is functional. It flashes green three times when SP module first receives power. It is yellow when SP is not functional.

  • Chassis Locate LED is white: It has been activated by the ILOM or Locate button.

Table A-13 describes the disk status based on the LEDs.

Table A-13 Disk Status of Oracle Server X5-8 and X6-8 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

Flashing

Flashing

Flashing

OK to Remove (Blue)

Off

Off

Off

A.5.7 Sun Server X4-8 Oracle Database Server LEDs

Table A-14 describes the color codes of the LEDs on Sun Server X4-8 Oracle Database Server.

Table A-14 Sun Server X4-8 Oracle Database Server LED Status Descriptions

Component LED Status

Sun Server X4-8 Oracle Database Server Back Panel PCIe Card Carriers (DPCC)

  • ATTN Button LED: Press to remove and to add the PCIe to the operating system.

  • Service Action Required (fault) LED is amber: There is a fault condition.

  • OK LED is green: PCIe is ready, and in use by the operating system.

Sun Server X4-8 Oracle Database Server hard drives

  • Hot Swap LED is blue: The hard drive can safely be removed.

  • Fault is amber: The hard drive is faulty.

  • Activity is green: Flashing indicates drive activity, and standby.

Sun Server X4-8 Oracle Database Server power supply

  • PSU Fault LED is amber: The power supply has a fault condition.

  • PSU OK LED is green: The power supply is on.

  • AC LED is green: AC is connected to the power supply.

Sun Server X4-8 Oracle Database Server service processor (SP) modules

  • 10/1000/1000Base-T Ethernet LED (left): Green indicates link is established at 1 gigabit. Amber and on indicates link is established at 100 megabits. Amber and off indicates link is established at 10 megabits.

  • 10/1000/1000Base-T Ethernet LED (bottom) is green: There is activity on the link.

  • Chassis Service Action Required (fault) LED is amber: There is a fault condition.

  • Chassis Power OK LED: Green indicates full power mode. It flashes quickly during SP boot when AC power cords are connected to the server. It flashes slowly in standby power mode.

  • Chassis Over-temperature LED is amber: The internal server temperature exceeds the upper threshold.

  • SP module OK LED: It is green and on when SP is functional. It flashes green three times when SP module first receives power. It is yellow when SP is not functional.

  • Chassis Locate LED is white: It has been activated by the ILOM or Locate button.

Table A-15 describes the disk status based on the LEDs.

Table A-15 Disk Status of Sun Server X4-8 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

Flashing

Flashing

Flashing

OK to Remove (Blue)

Off

Off

Off

A.5.8 Sun Server X2-8 Oracle Database Server LEDs

Table A-16 describes the color codes of the LEDs on Sun Server X2-8 Oracle Database Servers.

Table A-16 Sun Server X2-8 Oracle Database Server LED Status Descriptions

Component LED Status

Sun Server X2-8 Oracle Database Server Back Panel PCIe Express Modules (EM)

  • ATTN Button LED: Press to remove and to add the EM to the operating system.

  • Service Action Required (fault) LED is amber: There is a fault condition.

  • OK LED is green: EM is ready, and in use by the operating system.

Sun Server X2-8 Oracle Database Server hard drives

  • Hot Swap LED is blue: The hard drive can safely be removed.

  • Fault is amber: The hard drive is faulty.

  • Activity is green: Flashing indicates drive activity, and standby.

Sun Server X2-8 Oracle Database Server Network Express Modules (NEM)

  • 10 Gb Ethernet port Activity LED: Green indicates link is established at 100 megabits. Amber indicates link is at 10 megabits, and not at full capacity.

  • 10 Gb Ethernet port Link LED is green: There is activity on the link.

  • 10/1000/1000Base-T Ethernet LED (top): Green indicates link is established at 1 gigabit. Amber and on indicates link is established at 100 megabits. Amber and off indicates link is established at 10 megabits.

  • 10/1000/1000Base-T Ethernet LED (bottom) is green: There is activity on the link.

  • NEM Locate LED is white: It has been activated by the ILOM or Locate button.

  • OK to Remove LED is blue: Not used.

  • Service Action Required (fault) LED is amber: There is a fault condition.

  • Power OK LED is green: The system is powered on.

Sun Server X2-8 Oracle Database Server power supply

  • PSU Fault LED is amber: The power supply has a fault condition.

  • PSU OK LED is green: The power supply is on.

  • AC LED is green: AC is connected to the power supply.

Sun Server X2-8 Oracle Database Server service processor (SP) modules

  • 10/1000/1000Base-T Ethernet LED (left): Green indicates link is established at 1 gigabit. Amber and on indicates link is established at 100 megabits. Amber and off indicates link is established at 10 megabits.

  • 10/1000/1000Base-T Ethernet LED (bottom) is green: There is activity on the link.

  • Chassis Service Action Required (fault) LED is amber: There is a fault condition.

  • Chassis Power OK LED: Green indicates full power mode. It flashes quickly during SP boot when AC power cords are connected to the server. It flashes slowly in standby power mode.

  • Chassis Over-temperature LED is amber: The internal server temperature exceeds the upper threshold.

  • SP module OK LED: It is green and on when SP is functional. It flashes green three times when SP module first receives power. It is yellow when SP is not functional.

  • Chassis Locate LED is white: It has been activated by the ILOM or Locate button.

Table A-17 describes the disk status based on the LEDs.

Table A-17 Disk Status of Sun Server X2-8 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

Flashing

Flashing

Flashing

OK to Remove (Blue)

Off

Off

Off

A.5.9 Sun Fire X4800 Oracle Database Server LEDs

Table A-18 describes the color codes of the LEDs on Sun Fire X4800 Oracle Database Servers.

Table A-18 Sun Fire X4800 Oracle Database Server LED Status Descriptions

Component LED Status

Sun Fire X4800 Oracle Database Server Back Panel PCIe Express Modules (EM)

  • ATTN Button LED: Press to remove and to add the EM to the operating system.

  • Service Action Required (fault) LED is amber: There is a fault condition.

  • OK LED is green: EM is ready, and in use by the operating system.

Sun Fire X4800 Oracle Database Server hard drives

  • Hot Swap LED is blue: The hard drive can safely be removed.

  • Fault is amber: The hard drive is faulty.

  • Activity is green: Flashing indicates drive activity, and standby.

Sun Fire X4800 Oracle Database Server Network Express Modules (NEM)

  • 10 Gb Ethernet port Activity LED: Green indicates link is established at 100 megabits. Amber indicates link is at 10 megabits, and not at full capacity.

  • 10 Gb Ethernet port Link LED is green: There is activity on the link.

  • 10/1000/1000Base-T Ethernet LED (top): Green indicates link is established at 1 gigabit. Amber and on indicates link is established at 100 megabits. Amber and off indicates link is established at 10 megabits.

  • 10/1000/1000Base-T Ethernet LED (bottom) is green: There is activity on the link.

  • NEM Locate LED is white: It has been activated by the ILOM or Locate button.

  • OK to Remove LED is blue: Not used.

  • Service Action Required (fault) LED is amber: There is a fault condition.

  • Power OK LED is green: The system is powered on.

Sun Fire X4800 Oracle Database Server power supply

  • PSU Fault LED is amber: The power supply has a fault condition.

  • PSU OK LED is green: The power supply is on.

  • AC LED is green: AC is connected to the power supply.

Sun Fire X4800 Oracle Database Server service processor (SP) modules

  • 10/1000/1000Base-T Ethernet LED (left): Green indicates link is established at 1 gigabit. Amber and on indicates link is established at 100 megabits. Amber and off indicates link is established at 10 megabits.

  • 10/1000/1000Base-T Ethernet LED (bottom) is green: There is activity on the link.

  • Chassis Service Action Required (fault) LED is amber: There is a fault condition.

  • Chassis Power OK LED: Green indicates full power mode. It flashes quickly during SP boot when AC power cords are connected to the server. It flashes slowly in standby power mode.

  • Chassis Over-temperature LED is amber: The internal server temperature exceeds the upper threshold.

  • SP module OK LED: It is green and on when SP is functional. It flashes green three times when SP module first receives power. It is yellow when SP is not functional.

  • Chassis Locate LED is white: It has been activated by the ILOM or Locate button.

Table A-19 describes the disk status based on the LEDs.

Table A-19 Disk Status of Sun Fire X4800 Oracle Database Server Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

Flashing

Flashing

Flashing

OK to Remove (Blue)

Off

Off

Off

A.5.10 Exadata Storage Server X7-2 LEDs

The following table describes the color codes of the LEDs on Exadata Storage Server X7-2 Servers.

Table A-20 Exadata Storage Server X7-2 LED Status Descriptions

Component LED Status

Exadata Storage Server X7-2 fan module

  • Fan Status LED is off: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Exadata Storage Server X7-2 power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Exadata Storage Server X7-2 servers

  • OK to Remove LED is blue: The storage drive can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The system is running but the storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

  • Do-Not-Service LED is on: The storage server should not be powered off for services; otherwise it could cause a forced dismount of the Oracle ASM disk group and compromise data availability.

  • Do-Not-Service LED is off: The storage server can be powered off for services.

The following table describes the disk status based on the LEDs.

Table A-21 Disk Status of Exadata Storage Server X7-2 Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.11 Exadata Storage Server X5-2 Servers

Table A-22 describes the color codes of the LEDs on Exadata Storage Server X5-2 Servers.

Table A-22 LED Status Descriptions

Component LED Status

Exadata Storage Server X5-2 Servers fan module

  • Fan Status LED is off: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Exadata Storage Server X5-2 Servers power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Exadata Storage Server X5-2 Servers servers

  • OK to Remove LED is blue: A storage drive can safely be removed during a hot-swap procedure.

  • Service Action Required LED is amber: The storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-23 describes the disk status based on the LEDs.

Table A-23 Disk Status of Exadata Storage Server X5-2 Servers Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.12 Exadata Storage Server X4-2L Servers

Table A-24 describes the color codes of the LEDs on Exadata Storage Server X3-2 Servers.

Table A-24 LED Status Descriptions

Component LED Status

Exadata Storage Server X4-2L Servers fan module

  • Fan Status LED is green: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Exadata Storage Server X4-2L Servers power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Exadata Storage Server X4-2L Servers servers

  • OK to Remove LED is blue: A storage drive can safely be removed during a hot-swap procedure.

  • Service Action Required LED is amber: The storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-27 describes the disk status based on the LEDs.

Table A-25 Disk Status of Exadata Storage Server X4-2L Servers Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.13 Exadata Storage Server X3-2 Servers

Table A-26 describes the color codes of the LEDs on Exadata Storage Server X3-2 Servers.

Table A-26 LED Status Descriptions

Component LED Status

Exadata Storage Server X3-2 Servers fan module

  • Fan Status LED is green: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Exadata Storage Server X3-2 Servers power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Exadata Storage Server X3-2 Servers servers

  • OK to Remove LED is blue: A storage drive can safely be removed during a hot-swap procedure.

  • Service Action Required LED is amber: The storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-27 describes the disk status based on the LEDs.

Table A-27 Disk Status of Exadata Storage Server X3-2 Servers Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.14 Exadata Storage Server with Sun Fire X4270 M2 Servers

Table A-28 describes the color codes of the LEDs on Exadata Storage Server with Sun Fire X4270 M2 Servers.

Table A-28 LED Status Descriptions

Component LED Status

Exadata Storage Server with Sun Fire X4270 M2 Servers fan module

  • Fan Status LED is green: The system is powered on and the fan module is functioning correctly.

  • Fan Status LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Exadata Storage Server with Sun Fire X4270 M2 Servers power supply

  • OK to Remove LED is green: The power supply can be removed safely during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

Exadata Storage Server with Sun Fire X4270 M2 Servers servers

  • OK to Remove LED is blue: A storage drive can safely be removed during a hot-swap procedure.

  • Service Action Required LED is amber: The storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Table A-29 describes the disk status based on the LEDs.

Table A-29 Disk Status of Exadata Storage Server with Sun Fire X4270 M2 Servers Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

On

On

On

OK to Remove (Blue)

Off

On

On

A.5.15 Exadata Storage Server with Sun Fire X4275 Servers LEDs

Table A-30 describes the color codes of the LEDs on Exadata Storage Server with Sun Fire X4275 Serverss.

Table A-30 Exadata Storage Server with Sun Fire X4275 Servers LED Status Descriptions

Component LED Status

Exadata Storage Server with Sun Fire X4275 Servers

  • OK to Remove LED is blue: A storage drive can safely be removed during a hot-swap procedure.

  • Service Action Required LED is amber: The storage drive is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a storage drive fault.

  • OK/Activity LED is green: Data is being read from or written to the storage drive.

Exadata Storage Server with Sun Fire X4275 Servers fan module

  • Power/OK LED is green: The system is powered on and the fan module is functioning correctly.

  • Service Action Required LED is amber: The fan module is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a fan module fault.

Exadata Storage Server with Sun Fire X4275 Servers power supply

  • AC Present LED is green: Power supply can be removed during a hot-swap procedure.

  • Service Action Required LED is amber: The power supply is faulty. The front and rear panel Service Action Required LEDs are also lit if the system detects a power supply fault.

  • OK to Remove LED is blue: The power supply can safely be removed during a hot-swap procedure.

Table A-31 describes the disk status based on the LEDs.

Table A-31 Disk Status of Exadata Storage Server with Sun Fire X4275 Servers Based on LEDs

LED Predictive Failure Poor Performance Critical

Service Action Required (Amber)

Flashing

Flashing

On

OK to Remove (Blue)

Off

Flashing

Flashing

A.5.16 Sun Flash Accelerator F20 PCIe Card LEDs

Table A-32 describes the color codes of the LEDs on Sun Flash Accelerator F20 PCIe cards.

Table A-32 Sun Flash Accelerator F20 PCIe Card LED Status Descriptions

Component LED Status

FMod 3, 2, 1, 0

LED is green: It flashes when there is read/write activity in the corresponding FMod. It is on when the corresponding FMod is present.

ESM OK LED

LED is green: It is on when the ESM is adequately charged and capable of providing enough emergency power to retain data integrity in the event of a power interruption. It is off when the system is down, and it flashes when the ESM is charging.

ESM Service Required LED

LED is amber indicates the ESM is not retaining enough reserve power to support write-back mode. The card is functioning in write-through (caching) mode. Service is required.

Power LED

LED is on: Indicates the card is on.

A.5.17 Sun Datacenter InfiniBand Switch 36 Switch LEDs

Table A-33 describes the color codes of the LEDs on Sun Datacenter InfiniBand Switch 36 switches.

Table A-33 Sun Datacenter InfiniBand Switch 36 Switch LED Status Descriptions

Component LED Status

Sun Datacenter InfiniBand Switch 36 chassis

  • Locator LED is white: It flashes when identifying itself. It is on when there is no function, and off when disabled.

  • Attention LED is amber: There is a fault condition. It flashes when there is no function.

  • OK LED is green: Switch is functioning correctly. It flashes when there is no function.

Sun Datacenter InfiniBand Switch 36 link status

Link LED is green: It is on when link is established. It is off when link is down, and it flashes when there are symbol errors.

Sun Datacenter InfiniBand Switch 36 network management ports

  • Link speed LED: Green indicates 1000BASE-T. Amber indicates 100BASE-T. Off indicates no link. Flashing indicates no function.

  • Activity LED: Flashing indicates packet activity. On indicates no function. Off indicates no activity.

Sun Datacenter InfiniBand Switch 36 power supply

  • OK LED is green: Indicates 12 VDC is supplied. Flashing indicates no function.

  • Attention LED is amber: There is a fault, and 12 VDC shut down. Flashing indicates no function.

  • AC LED is green: AC power is present and good. Flashing indicates no function.

A.6 Parts and Repair Procedures for Oracle Database Servers

A.6.1 Oracle Server X7-2 Oracle Database Server Parts

Figure A-1 shows the front view of Oracle Server X7-2 Oracle Database Server.

Figure A-1 Front View of Oracle Server X7-2 Oracle Database Server

Description of Figure A-1 follows
Description of "Figure A-1 Front View of Oracle Server X7-2 Oracle Database Server"

Figure A-2 shows the rear view of Oracle Server X7-2 Oracle Database Server.

Figure A-2 Rear View of Oracle Server X7-2 Oracle Database Server

Description of Figure A-2 follows
Description of "Figure A-2 Rear View of Oracle Server X7-2 Oracle Database Server"

The following table lists the replaceable parts for Oracle Server X7-2 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-34 Replacement Parts for Oracle Server X7-2 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, slim-rail, 1U - 2U, snap in

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Server Into the Rack" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqrpu.html#scrolltoc

370-5621

3 volt lithium battery

DBO

FRU

See "Servicing the Battery (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqviw.html#scrolltoc

7093015

Drive, 600 GB 10K, SAS2, SFF

DBO

FRU

See "Servicing Storage Drives (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gquak.html#scrolltoc

7322171

Cable, interlock, 125 mm

DBO

FRU

See "Servicing Other Cables" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvev.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvjk.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

See Also: Oracle Exadata System Software User's Guide

7051223

Assembly, Dual 25 GbE SFP28 LP, X8 PCIe 3.0, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvjk.html#scrolltoc

7328735

Heat sink, CPU 1U

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqtmk.html#scrolltoc

7343599

Assembly, riser, 2S, 1U

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvft.html#scrolltoc

7330698

DIMM, 32 GB, RDIMM, DDR4, 2666

DBO

CRU

See "Servicing the DIMMs (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvkr.html#scrolltoc

7333459

Power supply, AC, A266, F, 12V, 1200W

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqunc.html#scrolltoc

  3. Replace the CMA.

7332895

HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module

DBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvmq.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvmq.html#scrolltoc

7340897

Cable, SAS3 to HBA

DBO

CRU

See "Servicing the Internal HBA Cables" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvav.html#scrolltoc

7331123

Fan module

HS

CRU

See "Servicing Fan Modules (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gquhg.html#scrolltoc

7095106

CPU, P-8160, 2.1 GHz, 150W, 24 core, (SR3B0)

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqtmk.html#scrolltoc

7341145

Assembly, 8DBP_SAS3, 1U

DBO

FRU

See "Servicing the Disk Backplane (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvap.html#scrolltoc

7317636

Assembly, motherboard, 1U

DBO

FRU

  1. See "Servicing the Motherboard (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvfa.html#scrolltoc

  2. Press F2 after restarting the server.

  3. Set the boot order.

A.6.2 Oracle Server X6-2 Oracle Database Server Parts

Figure A-3 shows the front view of Oracle Server X6-2 Oracle Database Server.

Figure A-3 Front View of Oracle Server X6-2 Oracle Database Server

Description of Figure A-3 follows
Description of "Figure A-3 Front View of Oracle Server X6-2 Oracle Database Server"

Figure A-4 shows the rear view of Oracle Server X6-2 Oracle Database Server.

The top hard disk drives are, from left to right HDD1, and HDD3. The lower drives are, from left to right, HDD0, and HDD2.

Figure A-4 Rear View of Oracle Server X6-2 Oracle Database Server

Description of Figure A-4 follows
Description of "Figure A-4 Rear View of Oracle Server X6-2 Oracle Database Server"

Table A-35 lists the replaceable parts for Oracle Server X6-2 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-35 Replacement Parts for Oracle Server X6-2 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, slim-rail, 1U - 2U, snap in

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Server Into the Rack" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40004191003899.html#scrolltoc

370-5621

3 volt lithium battery

DBO

FRU

See "Servicing the Battery (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40003f01423753.html#scrolltoc

542-0287

Drive, 600 GB 10K, SAS2, SFF

DBO

FRU

See "Servicing Storage Drives (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40000091011460.html#scrolltoc

7014226

Cable, interlock, 125 mm

DBO

FRU

See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/gnyov.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037409.html#scrolltoc
  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

    See Also: Oracle Exadata System Software User's Guide

7051223

Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y

DBO

CRU

Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

See "Servicing PCIe Cards (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037409.html#scrolltoc

7067728

Heat sink, CPU 1U

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40001d31037480.html#scrolltoc

7077680

Assembly, riser, 2S, 1U

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037394.html#scrolltoc

7078072

DIMM, 32 GB, RDIMM, DDR4, 2400

DBO

CRU

See "Servicing the DIMMs (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40003f01425075.html#scrolltoc

7079395

Power supply, AC, A256, F, 12V, 600W

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40000091014153.html#scrolltoc
  3. Replace the CMA.

7081071

Assembly, riser, single stack, 1U

DBO

CRU

See "Servicing PCIe Risers (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037394.html#scrolltoc

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

DBO

FRU

See "Servicing the Internal HBA Card (FRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/goeht.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

FRU

See "Servicing the Internal HBA Card (FRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/goeht.html#scrolltoc

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

DBO

CRU

See "Servicing the Internal HBA SAS Cable assembly" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40003eb1420346.html#scrolltoc

7089073

Fan module

HS

CRU

See "Servicing Fan Modules (CRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40000091014194.html#scrolltoc

7095106

CPU, E5-2699 v4, 2.2 GHz, 145W, 22 core, C-1 (SR1XD)

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40001d31037480.html#scrolltoc

7097205

Assembly, 8DBP, 1U/2U

DBO

FRU

See "Servicing the Disk Backplane (FRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40011771417642.html#scrolltoc

7098505

Assembly, motherboard, 1U

DBO

FRU

  1. See "Servicing the Motherboard (FRU)" in Oracle Server X6-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/z40011771418436.html#scrolltoc
  2. Press F2 after restarting the server.

  3. Set the boot order.

A.6.3 Oracle Server X5-2 Oracle Database Server Parts

Figure A-5 shows the front view of Oracle Server X5-2 Oracle Database Server.

Figure A-5 Front View of Oracle Server X5-2 Oracle Database Server

Description of Figure A-5 follows
Description of "Figure A-5 Front View of Oracle Server X5-2 Oracle Database Server"

Figure A-6 shows the rear view of Oracle Server X5-2 Oracle Database Server.

The top hard disk drives are, from left to right HDD1, and HDD3. The lower drives are, from left to right, HDD0, and HDD2.

Figure A-6 Rear View of Oracle Server X5-2 Oracle Database Server

Description of Figure A-6 follows
Description of "Figure A-6 Rear View of Oracle Server X5-2 Oracle Database Server"

Table A-36 lists the replaceable parts for Oracle Server X5-2 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-36 Replacement Parts for Oracle Server X5-2 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, slim-rail, 1U - 2U, snap in

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Server Into the Rack" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40004191003899.html

370-5621

3 volt lithium battery

DBO

FRU

See "Servicing the Battery (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40003f01423753.html

542-0287

Drive, 600 GB 10K, SAS2, SFF

DBO

FRU

See "Servicing Storage Drives (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40000091011460.html

7014226

Cable, interlock, 125 mm

DBO

FRU

See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/gnyov.html

7046442

Assembly, dual port, QDR CX3, host channel adapter

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037409.html
  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

    See Also: Oracle Exadata System Software User's Guide

7051223

Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y

DBO

CRU

Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

See "Servicing PCIe Cards (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037409.html

7067728

Heat sink, CPU 1U

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40001d31037480.html

7077680

Assembly, riser, 2S, 1U

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037394.html

7078072

DIMM, 32 GB, LRDIMM, DDR4, 2133

DBO

CRU

See "Servicing the DIMMs (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40003f01425075.html

7079395

Power supply, AC, A256, F, 12V, 600W

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40000091014153.html
  3. Replace the CMA.

7081071

Assembly, riser, single stack, 1U

DBO

CRU

See "Servicing PCIe Risers (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037394.html

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

DBO

FRU

See "Servicing the Internal HBA Card (FRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/goeht.html

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

FRU

See "Servicing the Internal HBA Card (FRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/goeht.html

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

DBO

CRU

See "Servicing the Internal HBA SAS Cable assembly" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40003eb1420346.html

7089073

Fan module

HS

CRU

See "Servicing Fan Modules (CRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40000091014194.html

7095106

CPU, E5-2699 v3, 2.3 GHz, 145W, 18 core, C-1 (SR1XD)

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40001d31037480.html

7097205

Assembly, 8DBP, 1U/2U

DBO

FRU

See "Servicing the Disk Backplane (FRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40011771417642.html

7098505

Assembly, motherboard, 1U

DBO

FRU

  1. See "Servicing the Motherboard (FRU)" in Oracle Server X5-2 Service Manual at http://docs.oracle.com/cd/E41059_01/html/E48320/z40011771418436.html
  2. Press F2 after restarting the server.

  3. Set the boot order.

A.6.4 Sun Server X4-2 Oracle Database Server Parts

The Exadata X4–2 Database Machine has several replaceable parts.

The following image shows the front view of Sun Server X4-2 Oracle Database Server.

Figure A-7 Front View of Sun Server X4-2 Oracle Database Server

Description of Figure A-7 follows
Description of "Figure A-7 Front View of Sun Server X4-2 Oracle Database Server"

The following image shows the rear view of Sun Server X4-2 Oracle Database Server.

Figure A-8 Rear View of Sun Server X4-2 Oracle Database Server

Description of Figure A-8 follows
Description of "Figure A-8 Rear View of Sun Server X4-2 Oracle Database Server"

The following tables lists the replaceable parts for Sun Server X4-2 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

See Also:

Oracle Server X4–2 Documentation Library at http://docs.oracle.com/cd/E36975_01/html/E38045/toc.html

Table A-37 Replacement Parts for Sun Server X4-2 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

7013526

Fan module

HS

CRU

See "Servicing Fan Modules (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091014194.html#scrolltoc

7018701

DIMM, 16 GB, DDR3, 2RX4, 1600, 1.35 V

DBO

CRU

See "Servicing the DIMMs (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40003f01425075.html#scrolltoc

7020774

Heat sink, CPU 1U, 60 mm FIN

DBO

FRU

See "Servicing Storage Drives (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091011460.html#scrolltoc

7027478

Disk Backplane, RoHS:Y

DBO

FRU

See "Servicing the Disk Backplane (FRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40011771417642.html#scrolltoc

7039841

Front indicator module

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000f91037394.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000f91037409.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

7047503

Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y

DBO

CRU

See "Servicing Storage Drives (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091011460.html#scrolltoc

7048707

Assembly, riser, double stack

DBO

CRU

See "Servicing PCIe Risers (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000f91037394.html#scrolltoc

7048710

1-slot PCI Express riser assembly

DBO

CRU

See "Servicing PCIe Risers (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000f91037394.html#scrolltoc

7051223

Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y

DBO

CRU

Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

7057184

Assembly, battery carrier remote

HS

FRU

"Replacing a Disk Controller BBU on a Database Server"

7058153

Assembly, motherboard, X4-2

DBO

FRU

  1. See "Servicing the Motherboard (FRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40011771418436.html

  2. Press F2 after restarting the server.

  3. Set the boot order.

7060020

Universal upgrade remote battery kit

EBO

FRU

"Replacing a Disk Controller BBU on a Database Server"

7060951

Power supply, AC, A256, F, 12V, 600W

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7069232

CPU, E5-2697 v2, 12-core, 2.7 GHz

DBO

FRU

See "Servicing Processors (FRU)" in Sun Server X4-2 Service Manual at http://docs.oracle.com/cd/E36975_01/html/E38045/z40001d31037480.html#scrolltoc

A.6.5 Sun Server X3-2 Oracle Database Server Parts

The Sun Server X3-2 Database Machine has several replaceable parts.

The following image shows the front view of Sun Server X3-2 Oracle Database Server.

Figure A-9 Front View of Sun Server X3-2 Oracle Database Server

Description of Figure A-9 follows
Description of "Figure A-9 Front View of Sun Server X3-2 Oracle Database Server"

The following image shows the rear view of Sun Server X3-2 Oracle Database Server.

Figure A-10 Rear View of Sun Server X3-2 Oracle Database Server

Description of Figure A-10 follows
Description of "Figure A-10 Rear View of Sun Server X3-2 Oracle Database Server"

The following table lists the replaceable parts for Sun Server X3-2 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-38 Replacement Parts for Sun Server X3-2 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

Battery, 3V, 390MAH, LITH, COIN

DBO

CRU

See "Servicing the Battery (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40003f01423753.html#scrolltoc

350-1719

Assembly, slim-rail, 1U-2U Snap-in

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Attach Tool-less Slide-Rail Assemblies" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Installation Guide at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000671011466.html#scrolltoc

375-3696

InfiniBand (CX2) dual port CX2 4xQDR PCI-e

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000f91037409.html#z40000f91407682

542-0388

300 GB - 10000 RPM SAS SFF disk assembly with one bracket

HS

CRU

See "Servicing Storage Drives (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000091011460.html#scrolltoc

Note: If the drive is part of the ZFS root pool, then see

http://docs.oracle.com/cd/E53394_01/html/E54801/gitgn.html

7013526

Fan module

HS

CRU

See "Servicing Fan Modules (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000091014194.html#scrolltoc

7018701

DIMM, 16 GB, DDR3, 2RX4, 1600, 1.35 V

DBO

CRU

See "Servicing the DIMMs (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40003f01425075.html#scrolltoc

7020774

Heat sink, CPU 1U, 60 mm FIN

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing Processors (FRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40001d31037480.html#scrolltoc

7026878

CPU, E5-2690, 2.9 GHz Intel 8-Core 135 W, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing Processors (FRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40001d31037480.html#scrolltoc

7027478

Disk Backplane, RoHS:Y

DBO

FRU

See "Servicing the Disk Backplane (FRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40011771417642.html#scrolltoc

7039841

Front indicator module

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000f91037394.html#scrolltoc

7048712

Motherboard assembly

DBO

FRU

See "Servicing the Motherboard (FRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40011771418436.html#scrolltoc

7047410

Power supply, AC, A256, 12V, 600W

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7047503

Assembly, 6 Gb SAS RAID disk PCIe HBA, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000f91037409.html#z40000f91407682

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

Note: Do not run any controller commands in the service manual when replacing the disk.

7048710

Riser assembly, double stack

DBO

CRU

See "Servicing PCIe Risers (CRU)" in Sun Server X3-2 (formerly Sun Fire X4170 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40000f91037394.html#scrolltoc

7050794

6 Gb SAS RAID PCI battery module (LiON), BBU-08, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/index.html

7051223

Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y

DBO

CRU

Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

7057184

Assembly, battery carrier remote

HS

FRU

"Replacing a Disk Controller BBU on a Database Server"

7060020

Universal upgrade remote battery kit

EBO

FRU

"Replacing a Disk Controller BBU on a Database Server"

A.6.6 Sun Fire X4170 M2 Oracle Database Server Parts

The following image shows the front view of Sun Fire X4170 M2 Oracle Database Server.

Figure A-11 Front View of Sun Fire X4170 M2 Oracle Database Server

Description of Figure A-11 follows
Description of "Figure A-11 Front View of Sun Fire X4170 M2 Oracle Database Server"
  1. Hard disk drives. The top drives are, from left to right HDD1, and HDD3. The lower drives are, from left to right, HDD0, and HDD2.

The following image shows the rear view of Sun Fire X4170 M2 Oracle Database Server.

Figure A-12 Rear View of Sun Fire X4170 M2 Oracle Database Server

Description of Figure A-12 follows
Description of "Figure A-12 Rear View of Sun Fire X4170 M2 Oracle Database Server"
  1. InfiniBand host channel adapter

  2. Gigabit Ethernet ports

The following table lists the replaceable parts for Sun Fire X4170 M2 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-39 Replacement Parts for Sun Fire X4170 M2 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

Battery, 3V, 390MAH, LITH, COIN

DBO

CRU

See "Servicing the Battery" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_71528

300-2233

Type A247 760 watt power supply, RoHS:Y

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/hotswap.html#50581538_pgfId-1098206

  3. Replace the CMA.

371-4889

2.93 GHz Intel 6-Core Xeon X5670, 12 MB, 95 W, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing CPUs" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_23425

371-4966

DIMM, 8 GB, DDR3, 2RX4, 1333

DBO

CRU

See "Servicing DDR3 DIMMs" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_71526

371-4919

1U Extended rail rack mount kit

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Installing the Server Into a Rack With Slide-Rails" in Sun Fire X4170, X4270, and X4275 Servers Installation Guide at http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html

371-4982

6 GB SAS RAID PCI battery module, RoHS:Y (LiON), BBU-08

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/index.html

371-4984

Six-Core Intel Xeon X5675 processors (3.06 GHz), 12 MB, 95 W, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing CPUs" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_23425

375-3696

InfiniBand (CX2) dual port CX2 4xQDR PCI-e

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_pgfId-1286564

375-3701

6 Gb SAS RAID disk PCIe HBA, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_pgfId-1286564

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

Note: Do not run any controller commands in the service manual when replacing the disk.

375-3617

Dual 10 GbE SFP+LP, RoHS:Y

DBO

CRU

Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

511-1548

8-slot Disk Backplane, SATA DVD, RoHS:Y

DBO

FRU

See "Servicing the Storage Drive Cage" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/infrastructure_x4170.html#50581544_71557

511-1489

Power Distribution Board, RoHS:Y

DBO

FRU

See "Servicing the Power Distribution Board" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/infrastructure_x4170.html#50581544_71558

530-3927

Cable, PDB, MB, 1U+2U, ribbon

DBO

CRU

See "Servicing Cables" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_82397

530-4228

Cable, mini-SAS, 36 POS LONG, LY, RoHS:Y

DBO

CRU

See "Servicing Cables" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_82397

530-4417

Cable, fan power, 1U

DBO

CRU

See "Servicing Fan Modules" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/hotswap.html#50581538_28930

530-4431

Cable, fan data, 1U

DBO

CRU

See "Servicing Cables" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_82397

540-7869

300 GB - 10000 RPM SAS SFF disk assembly with one bracket

HS

CRU

See "Servicing Storage Drives" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/hotswap.html#50581538_61628

Note: If the drive is part of the ZFS root pool, then see

http://docs.oracle.com/cd/E53394_01/html/E54801/gitgn.html

541-4081

System board assembly, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the Motherboard" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_98526

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

541-2075

Bus_bar, power, 1U+2U, RoHS:Y

DBO

FRU

See "Servicing the Power Distribution Board" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/infrastructure_x4170.html#50581544_71558

541-2545

Xeon Heatsink w/grease, RoHS:Y, 1U

DBO

FRU

See "Servicing CPUs" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_23425

541-4274

Fan board assembly, RoHS:Y

DBO

CRU

See "Servicing the Fan Board" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/infrastructure_x4170.html#50581544_pgfId-1286241

541-4276

Fan module, 40 x 56 mm, 15300 RPM fan, RoHS:Y

HS

CRU

See "Servicing Fan Modules" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/hotswap.html#50581538_28930

541-4275

Assembly, CONN-BRD-BRKT, SATA, 1U

DBO

FRU

See "Servicing the Paddle Board" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/infrastructure_x4170.html#50581544_71559

541-2636

Assembly, light pipes

DBO

FRU

See "Servicing the Front Control Panel Light Pipe Assembly" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/infrastructure_x4170.html#50581544_71563

541-2883

1-slot x8 PCI Express riser assembly, 1U, RoHS:Y

DBO

CRU

See "Servicing PCIe Risers" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_71527

541-2885

1-slot x16 PCI Express riser assembly, 1U,RoHS:Y

DBO

CRU

See "Servicing PCIe Risers" in Sun Fire X4170 M2 Server Service Manual at http://docs.oracle.com/cd/E19762-01/E22369-02/motherboard_x4170.html#50581523_71527

541-2732

USB assembly, DVD filler panel, RoHS:Y

DBO

CRU

See the external service label on the top cover for replacement instructions

A.6.7 Sun Fire X4170 Oracle Database Server Parts

The following image shows the front view of Sun Fire X4170 Oracle Database Server.

Figure A-13 Front View of Sun Fire X4170 Oracle Database Server

Description of Figure A-13 follows
Description of "Figure A-13 Front View of Sun Fire X4170 Oracle Database Server"
  1. Hard disk drives. The top drives are, from left to right HDD1, and HDD3. The lower drives are, from left to right, HDD0, and HDD2.

The following image shows the rear view of Sun Fire X4170 Oracle Database Server.

Figure A-14 Rear View of Sun Fire X4170 Oracle Database Server

Description of Figure A-14 follows
Description of "Figure A-14 Rear View of Sun Fire X4170 Oracle Database Server"
  1. InfiniBand host channel adapter

  2. Gigabit Ethernet ports

The following table lists the replaceable parts for Sun Fire X4170 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-40 Replacement Parts for Sun Fire X4170 Oracle Database Server

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

Panasonic BR2032 battery, RoHS:Y for system board

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering On and Off Oracle Exadata Rack" for additional information.

  2. See "Servicing the Battery" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_71528

300-2143

760 watt power supply, RoHS:Y

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/hotswap.html#50634786_11706

  3. Replace the CMA.

371-4288

4 GB registered DDR3-1333 DIMM, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing Memory Modules (DIMMs)" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_71526

371-4300

2.53 GHz Quad-Core Intel Xeon E5540, 8MB, 80W, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing CPUs" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_23425

371-4746

Battery module, RoHS:Y for 6 Gb SAS RAID disk PCI, BBU-07

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/index.html

371-4919

1U extended rail rack mount kit

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Installing the Server Into a Rack With Slide-Rails" in Sun Fire X4170, X4270, and X4275 Servers Installation Guide at http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html

375-3606

Sun dual-port QDR (40 Gb/s) InfiniBand host channel adapter PCIe, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_86021

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

375-3644

6 Gb SAS RAID disk PCIe HBA, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_86021

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

Note: Do not run any controller commands in the service manual when replacing the disk.

501-7696

Power distribution board, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the Power Distribution Board" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_71558

511-1283

8-slot disk backplane, SAS DVD, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the Storage Drive Backplane" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_pgfId-1287120

530-3927

Power distribution board to system board cable, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the Power Distribution Board" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_71558

530-4228

4x Mini SAS/SATA cable, SFF-8087 to SFF-8087, 690mm, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing Cables" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_78576

540-7355

146 GB 10 K RPM SAS disk assembly, RoHS:Y with the following:

  • Bracket

  • Disk

HS

CRU

See "Servicing Storage Drives" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/hotswap.html#50634786_61628

540-7868

146 GB 10 K RPM SAS disk assembly, RoHS:Y with the following:

  • Bracket

  • Disk

HS

CRU

See "Servicing Storage Drives" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/hotswap.html#50634786_61628

541-2075

Bus_bar, power, 1U+2U, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing CPUs" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_23425

541-2112

Fan power board, RoHS:Y with the following:

  • Top bracket

  • Bottom bracket

  • Fan board

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the Fan Power Boards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_pgfId-1286820

541-2542

System board assembly with tray, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the Motherboard Assembly" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_98526

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

541-2545

Xeon Heatsink with grease:RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing CPUs" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_23425

541-2636

Light pipe assembly, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the Front Control Panel Light Pipe Assembly" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_71563

541-2732

USB assembly, DVD filler panel, RoHS:Y

DBO

CRU

See the external service label on the top cover for replacement instructions

541-2802

Fan module, 40 mm 4-pole fan, Nidec, RoHS:Y

HS

CRU

See "Servicing Fan Modules" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/hotswap.html#50634786_28930

541-2883

1-slot x8 PCIe riser assembly with the following:

  • 1-slot x8 PCIe riser, RoHS:Y

  • Riser mounting bracket, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Risers" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_42797

541-2885

1-slot x16 PCIe riser assembly with the following:

  • 1-slot x16 PCIe riser, RoHS:Y

  • Riser mounting bracket, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Risers" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_42797

541-3512

Connector board assembly, SAS DVD with the following:

  • Bracket, RoHS:Y

  • Connector board, SATA DVD, RoHS:Y

  • Magnetic interlock switch, RoHS:Y

DBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing the DVD/USB Module" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_71556

A.6.8 Oracle Server X7-8 Oracle Database Server Parts

The following image shows the front view of Oracle Server X7-8 Oracle Database Server.

Figure A-15 Front View of Oracle Server X7-8 Oracle Database Server


Description of Figure A-15 follows
Description of "Figure A-15 Front View of Oracle Server X7-8 Oracle Database Server"

The following image shows the rear view of Oracle Server X7-8 Oracle Database Server.

Figure A-16 Rear View of Oracle Server X7-8 Oracle Database Server


Description of Figure A-16 follows
Description of "Figure A-16 Rear View of Oracle Server X7-8 Oracle Database Server"

The following table lists the replaceable parts for Oracle Server X7-8 Database Server.

Table A-41 Replacement Parts for Oracle Exadata X7-8 Oracle Database Server

Part Number Description Repair Category Coverage with Basic Warranty Repair Procedure

350-1662

Universal rail kit

IR

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Installing the Server Into a Rack" in Oracle Server X7-8 Installation Guide at http://docs.oracle.com/cd/E71925_01/html/E71931/gqpuu.html#scrolltoc

7335943

ASSY,6.4TB FLASH F640 NVMe AIC

DBO

CRU

See "Servicing PCIe Cards and Carriers (CRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsdm.html#scrolltoc

7091860

Assembly, fan module

DBO

FRU

See "Servicing Fan Modules (CRU) and Fan Frames (CRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsaw.html#scrolltoc

7046442

Dual port, QDR CX3, HCA

DBO

CRU

See "Servicing PCIe Cards and Carriers (CRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsdm.html#scrolltoc

7339763

Dual 25 GBE, SFP28 PCIe 3.0, LP

DBO

CRU

See "Servicing PCIe Cards and Carriers (CRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsdm.html#scrolltoc

7309735

Bus bar and midplane assembly

DBO

FRU

See "Replace the Midplane Assembly" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnseg.html#scrolltoc

7331378

PSU,AC,A265D,H,12V,245A

HS

CRU

See "Servicing Power Supplies (CRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsbd.html#scrolltoc

7090552

KIT, RACKRAIL, SPACER, BRACKETS, HARDWARE

IR

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Installing the Server Into a Rack" in Oracle Server X7-8 Installation Guide at http://docs.oracle.com/cd/E71925_01/html/E71931/gqpuu.html#scrolltoc

7330699

Assembly, RDIMM, 64 GB, DDR4, 2666, 4Rx4, 1.2v

DBO

CRU

See "Servicing DIMMs" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/grfoz.html#scrolltoc

7319341

Front indicator module

DBO

FRU

See "Servicing the Front Indicator Module (FRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnseu.html#scrolltoc

7345163

Dual PCIe card carrier

DBO

CRU

See "Servicing PCIe Cards and Carriers (CRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsdm.html#scrolltoc

7339736

CPU module (CMOD)

DBO

FRU

See "Servicing CPU Module (CMOD) Components (FRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsdq.html#scrolltoc

7339666

System module (SMOD)

DBO

FRU

See "Servicing System Module (SMOD) Components (FRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsem.html#scrolltoc

7309764

CPU heatsink

DBO

FRU

See "Servicing CPU Module (CMOD) Components (FRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsdq.html#scrolltoc

7347508

CPU, XEON P-8168, 2.7 GHZ, 205W, 24 CORE (SR37J)

DBO

FRU

See "Servicing CPU Module (CMOD) Components (FRU)" in Oracle Server X7-8 Service Manual at http://docs.oracle.com/cd/E71925_01/html/E71936/gnsdq.html#scrolltoc

A.6.9 Oracle Server X5-8 and X6-8 Oracle Database Server Parts

The following image shows the front view of Oracle Server X5-8 Oracle Database Server.

Figure A-17 Front View of Oracle Server X5-8 Oracle Database Server


Description of Figure A-17 follows
Description of "Figure A-17 Front View of Oracle Server X5-8 Oracle Database Server"

The following image shows the back view of Oracle Server X5-8 Oracle Database Server.

Figure A-18 Back View of Oracle Server X5-8 Oracle Database Server


Description of Figure A-18 follows
Description of "Figure A-18 Back View of Oracle Server X5-8 Oracle Database Server"

The following table lists the replaceable parts for Oracle Server X5-8 and X6-8 Oracle Database Server.

See Also:

Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/index.html

Table A-42 Replacement Parts for Oracle Exadata X5-8 and X6-8 Oracle Database Server

Part Number Description Repair Category Coverage with Basic Warranty Repair Procedure

350-1662

Universal rail kit

IR

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Rack Installation Instructions" in Oracle Server X5-8 Installation Guide at https://docs.oracle.com/cd/E56301_01/html/E56304/gnmnn.html

542-0287

SFF SAS, 600 GB, 10 K, SAS2, SFF

DBO

CRU

See "Servicing Storage Drives" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsej.html

7040622

Assembly, fan module

DBO

FRU

See "Servicing Fan Modules and Fan Frames" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsaw.html

7046442

Dual port, QDR CX3, HCA

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdm.html

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

DBO

CRU

See "Servicing the Host Bus Adapter (HBA) Card" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnshd.html

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

CRU

See "Servicing the Host Bus Adapter (HBA) Card" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnshd.html

7051223

Dual 10 GBE, I2 SFP + PCIe 2.0, LP

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdm.html

7054513

Bus bar and midplane assembly

DBO

FRU

See "Replace the Midplane Assembly" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnseg.html

7064767

Cable assembly, mini SAS r/a to straight, 280mm

DBO

CRU

See "Servicing the SAS Cable" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsgu.html

7067930

Fan module

HS

CRU

See "Servicing Fan Modules and Fan Frames" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsaw.html

7068817

Power supply

HS

CRU

See "Servicing Power Supply Units (PSUs)" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsbd.html

7069359

Assembly, rack mount

IR

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Rack Installation Instructions" in Oracle Server X5-8 Installation Guide at https://docs.oracle.com/cd/E56301_01/html/E56304/gnmnn.html

7073781

Assembly, LRDIMM, 32 GB, DDR3, 1600, 4Rx4, 1.35v

DBO

CRU

See "Servicing the CPU Module (CMOD) Components" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdq.html

7074696

Front indicator module

DBO

FRU

See "Servicing the Front Indicator Module (FIM)" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnseu.html

7077138

Dual PCIe card carrier

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdm.html

7077530

CPU module

DBO

FRU

See "Servicing the CPU Module (CMOD) Components" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdq.html

7078320

System module

DBO

FRU

See "Servicing System Module (SMOD) Components" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsem.html

7080100

CPU heatsink

DBO

FRU

See "Servicing the CPU Module (CMOD) Components" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdq.html

7111402

CPU, E7-8895, v3, 2.6 G, 175 W, 18 C, E0

DBO

FRU

See "Servicing the CPU Module (CMOD) Components" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdq.html

7100477

Sun Quad Port GbE PCIe 2.0 Low Profile Adapter, UTP

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Oracle Server X5-8 Service Manual at https://docs.oracle.com/cd/E56301_01/html/E56311/gnsdm.html

A.6.10 Sun Server X4-8 Oracle Database Server Parts

The following image shows the front view of Sun Server X4-8 Oracle Database Server.

Figure A-19 Front View of Sun Server X4-8 Oracle Database Server

Description of Figure A-19 follows
Description of "Figure A-19 Front View of Sun Server X4-8 Oracle Database Server"

The following image shows the rear view of Sun Server X4-8 Oracle Database Server.

Figure A-20 Rear View of Sun Server X4-8 Oracle Database Server

Description of Figure A-20 follows
Description of "Figure A-20 Rear View of Sun Server X4-8 Oracle Database Server"

The following table lists the replaceable parts for Sun Server X4-8 Oracle Database Servers.

See Also:

Sun Server X4-8 Documentation Library at http://docs.oracle.com/cd/E40591_01/

Table A-43 Replacement Parts for Sun Server X4-8 Oracle Database Servers

Part Number Description Repair Category Coverage with Basic Warranty Repair Procedure

350-1662

Universal rail kit

IR

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Rack Installation Instructions" in Sun Server X4-8 Installation Guide at http://docs.oracle.com/cd/E40591_01/html/E40305/gnmnn.html

542-0287

SFF SAS, 600 GB, 10 K, SAS2, SFF

DBO

CRU

See "Servicing Storage Drives" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsej.html

7040622

Assembly, fan module

DBO

FRU

See "Servicing Fan Modules and Fan Frames" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsaw.html

7046442

Dual port, QDR CX3, HCA

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdm.html

7047503

Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y

DBO

CRU

See "Servicing the Host Bus Adapter (HBA) Card" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnshd.html

7051223

Dual 10 GBE, I2 SFP + PCIe 2.0, LP

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdm.html

7054513

Bus bar and midplane assembly

DBO

FRU

See "Replace the Midplane Assembly" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnseg.html

7064767

Cable assembly, mini SAS r/a to straight, 280mm

DBO

CRU

See "Servicing the SAS Cable" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsgu.html

7067930

Fan module

HS

CRU

See "Servicing Fan Modules and Fan Frames" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsaw.html

7068817

Power supply

HS

CRU

See "Servicing Power Supply Units (PSUs)" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsbd.html

7069359

Assembly, rack mount

IR

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Rack Installation Instructions" in Sun Server X4-8 Installation Guide at http://docs.oracle.com/cd/E40591_01/html/E40305/gnmnn.html

7073781

Assembly, LRDIMM, 32 GB, DDR3, 1600, 4Rx4, 1.35v

DBO

CRU

See "Servicing the CPU Module (CMOD) Components" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdq.html

7074696

Front indicator module

DBO

FRU

See "Servicing the Front Indicator Module (FIM)" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnseu.html

7077138

Dual PCIe card carrier

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdm.html

7077530

CPU module

DBO

FRU

See "Servicing the CPU Module (CMOD) Components" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdq.html

7078320

System module

DBO

FRU

See "Servicing the System Module (SMOD) Components" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsem.html

7080100

CPU heatsink

DBO

FRU

See "Servicing the CPU Module (CMOD) Components" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdq.html

7080247

CPU, E7-8895, v2, 2.8 G, 155 W, 15 C, D1

DBO

FRU

See "Servicing the CPU Module (CMOD) Components" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdq.html

7100477

Sun Quad Port GbE PCIe 2.0 Low Profile Adapter, UTP

DBO

CRU

See "Servicing PCIe Cards and the Dual PCIe Card Carriers (DPCCs)" in Sun Server X4-8 Service Manual at http://docs.oracle.com/cd/E40591_01/html/E40317/gnsdm.html

A.6.11 Sun Server X2-8 Oracle Database Server Parts

The following image shows the front view of Sun Server X2-8 Oracle Database Server.

Figure A-21 Front View of Sun Server X2-8 Oracle Database Server

Description of Figure A-21 follows
Description of "Figure A-21 Front View of Sun Server X2-8 Oracle Database Server"
  1. Power supplies.

  2. Hard disk drives. The top drives are, from left to right, XL4, XL5, XL6, and XL7. The lower drives are, from left to right, XL0, XL1, XL2, and XL3.

  3. CPU modules. The modules are, from bottom to top, BL0, BL1, BL2, and BL3.

The following image shows the rear view of Sun Fire X4800 Oracle Database Server.

Figure A-22 Rear View of Sun Server X2-8 Oracle Database Server

Description of Figure A-22 follows
Description of "Figure A-22 Rear View of Sun Server X2-8 Oracle Database Server"
  1. Fan modules.

  2. Network Express Module.

  3. InfiniBand EM (CX2) dual port PCI Express modules.

The following table lists the replaceable parts for Sun Server X2-8 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-44 Replacement Parts for Sun Server X2-8 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

CMOD Battery

DBO

CRU

  1. See "How to Replace the CMOD Battery (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjeub.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

150-1204

3V, lithium battery for service processor, RoHS:Y

HS

CRU

 

300-2159

Power supply unit, AC, A239, F, 12V, 165A, 2Kw

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Removing and Installing a Power Supply (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfdt.html#scrolltoc

  3. Replace the CMA.

310-0225

Heatsink with grease, RoHS:Y, 1U

DBO

FRU

  1. See "Replacing a CPU and Heatsink Assembly (FRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjgrp.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

371-5057

CPU, Intel Xeon E7-8870, 10-core, 2.4GHz, 130 W

DBO

FRU

  1. See "Replacing a CPU and Heatsink Assembly (FRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjgrp.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

371-4742

Universal rack mount kit

DBO

FRU

  1. See "Installing the Server in a Rack Using the Universal Rack Mounting Kit" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Installation Guide at http://docs.oracle.com/cd/E20815_01/html/E20816/gjlel.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

371-4579

Assembly, fan module

HS

CRU

See "Removing and Installing a Fan Module (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfpo.html#scrolltoc

371-4982

6 Gb SAS RAID PCI battery module, RoHS:Y (LiON), BBU-08

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "To Remove the HBA" in Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/z4002f731006662.html#scrolltoc

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

371-5023

DIMM, 32 GB (2 x 16 GB), DDR3, 1066 MHZ

DBO

CRU

  1. See "Removing and Installing DIMMs (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfvw.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

375-3648

10 GbE Fabric Expansion Module (FEM)

DBO

CRU

  1. See "Removing and Installing a Fabric Expansion Module (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjmui.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

375-3605

InfiniBand EM (CX2) dual port CX2 4xQDR PCI-e EXP_MODULE

DBO

CRU

  1. See "Removing and Installing a PCIe EM (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfrl.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

375-3647

6 Gb/s SAS 2 REM 8-pin RAID HBA (REM) (on-board)

DBO

CRU

  1. See "Removing and Installing a RAID Expansion Module (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjldn.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

451-4586

System board assembly, CMOD

DBO

CRU for removal and insertion

FRU for replacement

  1. See "Adding, Removing, and Installing a CMOD (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfsd.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

511-1062

Assembly, backplane HDD BD

DBO

FRU

  1. See "Replacing the Hard Drive Backplane (FRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjgqc.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

530-3936

Multi-port dongle cable adapter, RoHS:Y

HS

CRU

See "Removing and Installing the Multiport Cable" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjukk.html#scrolltoc

530-4214

Cable, SAS long

DBO

FRU

  1. See "Hard Drive Backplane Cable Routing and Designations" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjkuz.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

530-4215

Cable, SAS short

DBO

FRU

  1. See "Hard Drive Backplane Cable Routing and Designations" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjkuz.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

530-4216

Cable, disk plane, power

DBO

FRU

  1. See "Hard Drive Backplane Cable Routing and Designations" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjkuz.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

540-7640

Subassembly module: assembly, chassis, midplane, X4800

DBO

FRU

  1. See "Removing and Installing the Subassembly Module (FRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjgnp.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

540-7645

Assembly, service processor, X4800

HS

CRU

See "Removing and Installing the Service Processor Module (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfvy.html#scrolltoc

540-7637

Network Express Module (NEM) - 4x 10 GbE + PassThru for 4x GbE NEM

HS

CRU

See "Removing and Installing a NEM or a NEM Filler (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfse.html#scrolltoc

540-7672

Assembly, module, fan interconnect

DBO

FRU

  1. See "Replacing a Fan Module Controller Board (FRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjmts.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

542-0300

300 GB 10 K RPM 2.5 inch SAS HDD and bracket

HS

CRU

See "Removing and Installing a Hard Drive (CRU)" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual at http://docs.oracle.com/cd/E20815_01/html/E20819/gjfex.html#scrolltoc

Note: If the drive is part of the ZFS root pool, then see http://docs.oracle.com/cd/E53394_01/html/E54801/gitgn.html

A.6.12 Sun Fire X4800 Oracle Database Server Parts

The following image shows the front view of Sun Fire X4800 Oracle Database Server.

Figure A-23 Front View of Sun Fire X4800 Oracle Database Server

Description of Figure A-23 follows
Description of "Figure A-23 Front View of Sun Fire X4800 Oracle Database Server"
  1. Power supplies.

  2. Hard disk drives. The top drives are, from left to right, XL4, XL5, XL6, and XL7. The lower drives are, from left to right, XL0, XL1, XL2, and XL3.

  3. CPU modules. The modules are, from bottom to top, BL0, BL1, BL2, and BL3.

The following image shows the rear view of Sun Fire X4800 Oracle Database Server.

Figure A-24 Rear View of Sun Fire X4800 Oracle Database Server

Description of Figure A-24 follows
Description of "Figure A-24 Rear View of Sun Fire X4800 Oracle Database Server"
  1. Fan modules.

  2. Network Express Module.

  3. InfiniBand EM (CX2) dual port PCI Express modules.

The following table lists the replaceable parts for Sun Fire X4800 Oracle Database Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-45 Replacement Parts for Sun Fire X4800 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

CMOD Battery

DBO

CRU

  1. See "How to Replace the CMOD Battery (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjeub.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

150-1204

3V, lithium battery for service processor, RoHS:Y

HS

CRU

 

300-2159

Power supply unit, AC, A239, F, 12V, 165A, 2Kw

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Removing and Installing a Power Supply (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfdt.html#scrolltoc

  3. Replace the CMA.

310-0225

Heatsink with grease, RoHS:Y, 1U

DBO

FRU

  1. See "Replacing a CPU and Heatsink Assembly (FRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjgrp.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

371-4860

CPU, Intel X7560,2.26 G, 130 W, 8CR

DBO

FRU

  1. See "Replacing a CPU and Heatsink Assembly (FRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjgrp.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

371-4742

Universal rack mount kit

DBO

FRU

  1. See "Installing the Server in a Rack Using the Universal Rack Mounting Kit" in Sun Server X2-8 (formerly Sun Fire X4800 M2) Installation Guide at http://docs.oracle.com/cd/E20815_01/html/E20816/gjlel.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

371-4579

Assembly, fan module

HS

CRU

See "Removing and Installing a Fan Module (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfpo.html#scrolltoc

371-4982

6 Gb SAS RAID PCI battery module, RoHS:Y (LiON), BBU-08

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "To Remove the HBA" in Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/z4002f731006662.html#scrolltoc

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

375-3648

10 GbE Fabric Expansion Module (FEM)

DBO

CRU

  1. See "Removing and Installing a Fabric Expansion Module (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjmui.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

375-3605

InfiniBand EM (CX2) dual port CX2 4xQDR PCI-e EXP_MODULE

DBO

CRU

  1. See "Removing and Installing a PCIe EM (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfrl.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

375-3647

6 Gb/s SAS 2 REM 8-pin RAID HBA (REM) (on-board)

DBO

CRU

  1. See "Removing and Installing a RAID Expansion Module (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjldn.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

511-1062

Assembly, backplane HDD BD

DBO

FRU

  1. See "Replacing the Hard Drive Backplane (FRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjgqc.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

530-3936

Multi-port dongle cable adapter, RoHS:Y

HS

CRU

See "Removing and Installing the Multi port Cable" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjukk.html#scrolltoc

530-4214

Cable, SAS long

DBO

FRU

  1. See "Hard Drive Backplane Cable Routing and Designations" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjkuz.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

530-4215

Cable, SAS short

DBO

FRU

  1. See "Hard Drive Backplane Cable Routing and Designations" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjkuz.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

530-4216

Cable, disk plane, power

DBO

FRU

  1. See "Hard Drive Backplane Cable Routing and Designations" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjkuz.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

540-7640

Subassembly module: assembly, chassis, midplane, X4800

DBO

FRU

  1. See "Removing and Installing the Subassembly Module (FRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjgnp.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

540-7645

Assembly, service processor, X4800

HS

CRU

See "Removing and Installing the Service Processor Module (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfvy.html#scrolltoc

540-7637

Network Express Module (NEM) - 4x 10 GbE + PassThru for 4x GbE NEM

HS

CRU

See "Removing and Installing a NEM or a NEM Filler (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfse.html#scrolltoc

540-7672

Assembly, module, fan interconnect

DBO

FRU

  1. See "Removing and Installing a Fan Module (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjmts.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

541-3426

Assembly, Blade, CPU SMP module (CMOD)

DBO

CRU for removal and insertion

FRU for replacement

  1. See "Adding, Removing, and Installing a CMOD (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfsd.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

542-0246

DIMM, 16 GB (2 x 8 GB), DDR3, 1066MHZ

DBO

CRU

  1. See "Removing and Installing DIMMs (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfvw.html#scrolltoc

  2. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

542-0300

300 GB 10 K RPM 2.5-inch SAS HDD and bracket

HS

CRU

See "Removing and Installing a Hard Drive (CRU)" in Sun Fire X4800 Server Service Manual at http://docs.oracle.com/cd/E19140-01/html/821-0282/gjfex.html#scrolltoc

Note: If the drive is part of the ZFS root pool, then see http://docs.oracle.com/cd/E53394_01/html/E54801/gitgn.html

A.7 Parts for Exadata Storage Servers

The following tables list the part for Exadata Storage Servers:

A.7.1 High Capacity Oracle Exadata Storage Server X7-2 Parts

The following figure shows the front view of the High Capacity Oracle Exadata Storage Server X7-2 Server.

Figure A-25 Front View of High Capacity Oracle Exadata Storage Server X7-2 Servers


Description of Figure A-25 follows
Description of "Figure A-25 Front View of High Capacity Oracle Exadata Storage Server X7-2 Servers"

The following figure shows the rear view of the High Capacity Oracle Exadata Storage Server X7-2 Server.

Figure A-26 Rear View of High Capacity Oracle Exadata Storage Server X7-2 Servers


Description of Figure A-26 follows
Description of "Figure A-26 Rear View of High Capacity Oracle Exadata Storage Server X7-2 Servers"

The following table lists the replaceable parts for High Capacity Oracle Exadata Storage Server X7-2 Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-46 Replacement Parts for High Capacity Oracle Exadata Storage Server X7-2 Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Server in the Rack" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqqca.html#scrolltoc

370-5621

3 volt lithium battery

EBO

FRU

See "Servicing the Battery (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtff.html#scrolltoc

7322171

Indicator assembly, LFIM

EBO

FRU

See "Servicing the Front LED Indicator Module (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtpg.html#scrolltoc

7341141

12-Disk backplane assembly

EBO

FRU

See "Servicing the Disk Backplane (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtsb.html#scrolltoc

7333459

Power Supply, A266, 1200W, AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtag.html#scrolltoc

  3. Replace the CMA.

7322166

Fan assembly, 2U

HS

FRU

See "Servicing Fan Modules (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtak.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcq.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

7322160

Heat sink, CPU

EBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtmk.html#scrolltoc

7332759

Assembly, drive, 10 TB, 3.5 inch, SAS/7200rpm

HS

FRU

See "Servicing Storage Drives (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcs.html#scrolltoc

7330697

DIMM, 16 GB, RDIMM, DDR4, 2666

EBO

FRU

See "Servicing the DIMMs (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcm.html#scrolltoc

7332895

HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module

EBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2L Service Manual at hhttp://docs.oracle.com/cd/E72463_01/html/E72474/gqtjv.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

EBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2L Service Manual at hhttp://docs.oracle.com/cd/E72463_01/html/E72474/gqtjv.html#scrolltoc

7315464

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

EBO

FRU

See "Servicing SAS Cables (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqthb.html#scrolltoc

7341587

M.2,150GB,SATA,22x80mm,SSD,INTEL, DC S3520

EBO

FRU

See "Servicing the Internal M.2 Flash SSDs (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/grlly.html#scrolltoc

7335943

Assembly, 6.4 TB eMLC flash F640 NVMe card

EBO

FRU

See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcq.html#scrolltoc

7347511

CPU, XEON S-4114 , 2.2G, 85W, 10 CORE, (SR3GK)

EBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtmk.html#scrolltoc

7335280

ASM, MB MECH, 2U

EBO

FRU

See "Servicing the Motherboard Assembly (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtwc.html#scrolltoc

A.7.2 Extreme Flash Oracle Exadata Storage Server X7-2 Parts

The Exadata Extreme Flash X7-2 Server has several replaceable parts.

The following figure shows the front view of the Extreme Flash Oracle Exadata Storage Server X7-2 server.

Figure A-27 Front View of Extreme Flash Oracle Exadata Storage Server X7-2 Servers


Description of Figure A-27 follows
Description of "Figure A-27 Front View of Extreme Flash Oracle Exadata Storage Server X7-2 Servers"

The following figure shows the rear view of the Extreme Flash Oracle Exadata Storage Server X7-2 server.

Figure A-28 Rear View of Extreme Flash Oracle Exadata Storage Server X7-2 Servers


Description of Figure A-28 follows
Description of "Figure A-28 Rear View of Extreme Flash Oracle Exadata Storage Server X7-2 Servers"

The following table lists the replaceable parts for Extreme Flash Oracle Exadata Storage Server X7-2 servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-47 Replacement Parts for Extreme Flash Oracle Exadata Storage Server X7-2

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Server in the Rack" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqqca.html#scrolltoc

370-5621

3 volt lithium battery

EBO

FRU

See "Servicing the Battery (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtff.html#scrolltoc

7322171

Indicator assembly, LFIM

EBO

FRU

See "Servicing the Front LED Indicator Module (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtpg.html#scrolltoc

7341141

12-Disk backplane assembly

EBO

FRU

See "Servicing the Disk Backplane (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtsb.html#scrolltoc

7333459

Power Supply, A266, 1200W, AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtag.html#scrolltoc

  3. Replace the CMA.

7322166

Fan assembly, 2U

HS

FRU

See "Servicing Fan Modules (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtak.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcq.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

7322160

Heat sink, CPU

EBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtmk.html#scrolltoc

7332759

Assembly, drive, 10 TB, 3.5 inch, SAS/7200rpm

HS

FRU

See "Servicing Storage Drives (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcs.html#scrolltoc

7330697

DIMM, 16 GB, RDIMM, DDR4, 2666

EBO

FRU

See "Servicing the DIMMs (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcm.html#scrolltoc

7332895

HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module

EBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2L Service Manual at hhttp://docs.oracle.com/cd/E72463_01/html/E72474/gqtjv.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

EBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2L Service Manual at hhttp://docs.oracle.com/cd/E72463_01/html/E72474/gqtjv.html#scrolltoc

7315464

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

EBO

FRU

See "Servicing SAS Cables (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqthb.html#scrolltoc

7341587

M.2,150GB,SATA,22x80mm,SSD,INTEL, DC S3520

EBO

FRU

See "Servicing the Internal M.2 Flash SSDs (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/grlly.html#scrolltoc

7335943

Assembly, 6.4 TB eMLC flash F640 NVMe card

EBO

FRU

See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcq.html#scrolltoc

7347511

CPU, XEON S-4114 , 2.2G, 85W, 10 CORE, (SR3GK)

EBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtmk.html#scrolltoc

7335280

ASM, MB MECH, 2U

EBO

FRU

See "Servicing the Motherboard Assembly (FRU)" in Oracle Server X7-2L Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtwc.html#scrolltoc

A.7.3 High Capacity Exadata Storage Server X6-2 Servers Parts

The following table lists the replaceable parts for High Capacity Exadata Storage Server X6-2 Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-48 Replacement Parts for High Capacity Exadata Storage Server X6-2 Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Server in the Rack" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/z40004191003899.html#scrolltoc

370-5621

3 volt lithium battery

EBO

FRU

See "Servicing the Battery" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/z40000f91037456.html#scrolltoc

7014226

Cable, interlock, 125 mm

EBO

FRU

See "Servicing SAS Cables" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goitq.html#scrolltoc

7017231

Indicator assembly, right

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goity.html#scrolltoc

7023515

Disk backplane assembly, 2 rear

EBO

FRU

See "Servicing the Storage Drive Backplanes" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goitv.html#scrolltoc

7044130

Power Supply, A258, 1000W, AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center_rotate

HS

FRU

See "Servicing Fan Modules" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/z40000091014194.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/z40000f91037409.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

7064884

Heat sink, CPU

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goiwq.html#scrolltoc

7066824

Assembly, drive, 8 TB, 3.5 inch, SAS/7200rpm

HS

FRU

See "Servicing Storage Drives and Rear Drives" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/z40000091011460.html#scrolltoc

7069337

Assembly, backplane, 12X3.5, W/SAS expansion, 2U

EBO

FRU

See "Servicing the Storage Drive Backplanes" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goitv.html#scrolltoc

7078070

DIMM, 16 GB, RDIMM, DDR4, 2400

EBO

FRU

See "Servicing the DIMMS" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/ceicjagi.html#scrolltoc

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

EBO

FRU

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goivo.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

EBO

FRU

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goivo.html#scrolltoc

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

EBO

FRU

See "Servicing SAS Cables" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goitq.html#scrolltoc

7090170

Flash drive, MLC, OSA ID, USB, 8 GB

EBO

FRU

See "Servicing the Internal USB Flash Drive" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/ceiicfbd.html#scrolltoc

7090698

Assembly, 3.2 TB eMLC flash F320 NVMe card

EBO

FRU

See Oracle Flash Accelerator F320 PCIe Card User Guide at http://docs.oracle.com/cd/E65386_01/html/E65387/index.html

7095102

CPU, E5-2630 V4, 2.2G, 85W, 10 CORE, R-2 (SR206)

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goiwq.html#scrolltoc

7096185

Assembly, indicator, left

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goity.html#scrolltoc

7098504

ASM, MOBO tray

EBO

FRU

See "Servicing the Motherboard Assembly" in Oracle Exadata Storage Server X6-2 High Capacity Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63692/goiup.html#scrolltoc

A.7.4 Extreme Flash Exadata Storage Server X6-2 Servers Parts

The Exadata Extreme Flash X6-2 Server has several replaceable parts.

The following table lists the replaceable parts for Extreme Flash Exadata Storage Server X6-2 Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-49 Replacement Parts for Extreme Flash Exadata Storage Server X6-2 Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Storage Server in the Rack" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/z40004191003899.html#scrolltoc

370-5621

3 volt lithium battery

EBO

FRU

See "Servicing the Battery" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/z40000f91037456.html#scrolltoc

7014226

Cable, interlock, 125 mm

EBO

FRU

See "Servicing NVMe Cables" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goioo.html#scrolltoc

7017231

Indicator assembly, right

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goipz.html#scrolltoc

7044130

Power Supply, A258, 1000 Watt AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center_rotate

HS

FRU

See "Servicing Fan Modules" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/z40000091014194.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/z40000f91037409.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

7064634

Assembly, switch, PCI-e, X8, IDT

EBO

FRU

See "Servicing PCIe Cards" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/z40000f91037409.html#scrolltoc

7064884

Heat sink, CPU

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goink.html#scrolltoc

7078070

DIMM, 16 GB, RDIMM, DDR4, 2400

EBO

FRU

See "Servicing the DIMMs" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/ceicjagi.html#scrolltoc

7090170

Flash drive, MLC, OSA ID, USB, 8 GB

EBO

FRU

See "Servicing the Internal USB Flash Drives" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/ceiicfbd.html#scrolltoc

7093483

ASM, BP, Ultra-NVME

EBO

FRU

See “Servicing the Storage Drive Backplane” in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goimw.html#scrolltoc

7093931

Assembly, SSD, 3.2 TB, eMLC-NAND, SFF-2.5 inch NVMe 1.0, X4

HS

FRU

See "Servicing the NVMe Storage Drive" in Oracle 3.2 TB NVMe SSD User Guide at http://docs.oracle.com/cd/E65386_01/html/E65389/z40002cc9112.html#scrolltoc

7095102

CPU, E5-2630 V4, 2.2G, 85W, 10 CORE, R-2 (SR206)

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goink.html#scrolltoc

7095801

Cable, NVME, HD41, RA-HD4i, STR, 6XBUNDLE

EBO

FRU

See "Servicing NVMe Cables" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goioo.html#scrolltoc

7096185

Assembly, indicator, left

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goipz.html#scrolltoc

7098504

ASM, MOBO tray

EBO

FRU

See “Servicing the Motherboard Assembly” in Oracle Exadata Storage Server X6-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E62172_01/html/E63689/goiqp.html#scrolltoc

A.7.5 High Capacity Exadata Storage Server X5-2 Servers Parts

The High Capacity Exadata Storage Server X5-2 Server has several replaceable parts.

The following image shows the front view of High Capacity Exadata Storage Server X5-2 Servers.

Figure A-29 Front View of High Capacity Exadata Storage Server X5-2 Servers

Description of Figure A-29 follows
Description of "Figure A-29 Front View of High Capacity Exadata Storage Server X5-2 Servers"

The following image shows the rear view of High Capacity Exadata Storage Server X5-2 Servers.

Figure A-30 Rear View of High Capacity Exadata Storage Server X5-2 Servers

Description of Figure A-30 follows
Description of "Figure A-30 Rear View of High Capacity Exadata Storage Server X5-2 Servers"

The following table lists the replaceable parts for High Capacity Exadata Storage Server X5-2 Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-50 Replacement Parts for High Capacity Exadata Storage Server X5-2 Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Server in the Rack" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/z40004191003899.html#scrolltoc

370-5621

3 volt lithium battery

EBO

FRU

See "Servicing the Battery" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/z40000f91037456.html#scrolltoc

7014226

Cable, interlock, 125 mm

EBO

FRU

See "Servicing SAS Cables" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goitq.html#scrolltoc

7017231

Indicator assembly, right

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goity.html#scrolltoc

7023515

Disk backplane assembly, 2 rear

EBO

FRU

See "Servicing Storage Drives and Rear Drives" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/z40000091011460.html#scrolltoc

7044130

Power Supply, A258, 1000W, AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center_rotate

HS

FRU

See "Servicing Fan Modules" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/z40000091014194.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/z40000f91037409.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

7064884

Heat sink, CPU

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goiwq.html#scrolltoc

7066824

Assembly, drive, 4 TB, 3.5 inch, SAS/7200rpm

HS

FRU

See "Servicing Storage Drives and Rear Drives" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/z40000091011460.html#scrolltoc

7069337

Assembly, backplane, 12X3.5, W/SAS expansion, 2U

EBO

FRU

See "Servicing the Storage Drive Backplanes" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goitv.html#scrolltoc

7078070

DIMM, 8 GB, RDIMM, DDR4, 2133

EBO

FRU

See "Servicing the DIMMs" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/ceicjagi.html#scrolltoc

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

EBO

FRU

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goivo.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

EBO

FRU

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goivo.html#scrolltoc

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

EBO

FRU

See "Servicing SAS Cables" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goitq.html#scrolltoc

7090170

Flash drive, MLC, OSA ID, USB, 8 GB

EBO

FRU

See "Servicing the Internal USB Flash Drive" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/ceiicfbd.html#scrolltoc

7090698

Assembly, 1.6 TB eMLC flash F160 NVMe card, Aura 3.0 with LP BRKT

EBO

FRU

See Oracle Flash Accelerator F160 PCIe Card User Guide at http://docs.oracle.com/cd/E54943_01/html/E54947/index.html

7095102

CPU, E5-2630 V3, 2.4G, 85W, 8 CORE, R-2 (SR206)

EBO

 

See "Servicing Processors" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goiwq.html#scrolltoc

7096185

Assembly, indicator, left

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goity.html#scrolltoc

7098504

ASM, MOBO tray

EBO

FRU

See "Servicing the Motherboard Assembly" in Oracle Exadata Storage Server X5-2 High Capacity Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55080/goiup.html#scrolltoc

A.7.6 Extreme Flash Exadata Storage Server X5-2 Servers Parts

The following image shows the front view of Extreme Flash Exadata Storage Server X5-2 Servers.

Figure A-31 Front View of Extreme Flash Exadata Storage Server X5-2 Servers

Description of Figure A-31 follows
Description of "Figure A-31 Front View of Extreme Flash Exadata Storage Server X5-2 Servers"

The following image shows the rear view of Extreme Flash Exadata Storage Server X5-2 Servers.

Figure A-32 Rear View of Extreme Flash Exadata Storage Server X5-2 Servers

Description of Figure A-32 follows
Description of "Figure A-32 Rear View of Extreme Flash Exadata Storage Server X5-2 Servers"

The following table lists the replaceable parts for Extreme Flash Exadata Storage Server X5-2 Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-51 Replacement Parts for Extreme Flash Exadata Storage Server X5-2 Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Reinstall the Storage Server in the Rack" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/z40004191003899.html#scrolltoc

370-5621

3 volt lithium battery

EBO

FRU

See "Servicing the Battery" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/z40000f91037456.html#scrolltoc

7014226

Cable, interlock, 125 mm

EBO

FRU

See "Servicing NVMe Cables" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goioo.html#scrolltoc

7017231

Indicator assembly, right

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goipz.html#scrolltoc

7044130

Power Supply, A258, 1000 Watt AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center_rotate

HS

FRU

See "Servicing Fan Modules" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/z40000091014194.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/z40000f91037409.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile 
    

7064634

Assembly, switch, PCI-e, X8, IDT

EBO

FRU

See "Servicing PCIe Cards" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/z40000f91037409.html#scrolltoc

7064884

Heat sink, CPU

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goink.html#scrolltoc

7078070

DIMM, 8 GB, RDIMM, DDR4, 2133

EBO

FRU

See "Servicing the DIMMs" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/ceicjagi.html#scrolltoc

7090170

Flash drive, MLC, OSA ID, USB, 8 GB

EBO

FRU

See "Servicing the Internal USB Flash Drives" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/ceiicfbd.html#scrolltoc

7093483

ASM, BP, Ultra-NVME

EBO

FRU

See "Servicing the Storage Drive Backplane" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goimw.html#scrolltoc

7093931

Assembly, SSD, 1.6 TB, eMLC-NAND, SFF-2.5 inch NVMe 1.0, X4

HS

FRU

See "Servicing the NVMe Storage Drive" in Oracle 1.6 TB NVMe SSD User Guide at http://docs.oracle.com/cd/E54943_01/html/E54944/z40002cc9112.html#scrolltoc

7095102

CPU, E5-2630 V3, 2.4G, 85W, 8 CORE, R-2 (SR206)

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goink.html#scrolltoc

7095801

Cable, NVME, HD41, RA-HD4i, STR, 6XBUNDLE

EBO

FRU

See "Servicing NVMe Cables" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goioo.html#scrolltoc

7096185

Assembly, indicator, left

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goipz.html#scrolltoc

7098504

ASM, MOBO tray

EBO

FRU

See "Servicing the Motherboard Assembly" in Oracle Exadata Storage Server X5-2 Extreme Flash Service Manual at http://docs.oracle.com/cd/E41033_01/html/E55031/goiqp.html#scrolltoc

A.7.7 Exadata Storage Server X4-2L Servers Parts

The following image shows the front view of Exadata Storage Server X4-2L Servers. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.

Figure A-33 Front View of Exadata Storage Server X4-2L Servers

Description of Figure A-33 follows
Description of "Figure A-33 Front View of Exadata Storage Server X4-2L Servers"

The following image shows the rear view of Exadata Storage Server X4-2L Servers.

Figure A-34 Rear View of Exadata Storage Server X4-2L Servers

Description of Figure A-34 follows
Description of "Figure A-34 Rear View of Exadata Storage Server X4-2L Servers"

The following table lists the replaceable parts for Exadata Storage Server X4-2L Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-52 Replacement Parts for Exadata Storage Server X4-2L Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

371-5002

USB drive, 4 GB

EBO

CRU

See "Servicing the Internal USB Flash Drives (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/ceiicfbd.html#scrolltoc

7014226

Cable, interlock, 125 mm

EBO

FRU

See "Servicing Cables (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/baecfjbc.html#scrolltoc

7014391

Expander assembly, 2U

EBO

FRU

See "Servicing the SAS Expander Module (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/ceieidja.html#scrolltoc

7106353

4 TB 7200 rpm SAS HDD with bracket

DBO

CRU

See "Servicing Storage Drives and Rear Drives (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091011460.html#scrolltoc

7017231

Indicator assembly, right

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31014236.html#scrolltoc

7018701

DIMM, 16 GB, DDR3, 1600, 2Rx4, 1.35V

EBO

CRU

See "Servicing the DIMMs (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/ceicjagi.html#scrolltoc

7020486

DIMM, 8 GB, DDR3, 1600, 2Rx4, 1.35V

EBO

CRU

See "Servicing the DIMMs (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/ceicjagi.html#scrolltoc

7020776

Heatsink, CPU, 2U, 60 MM FIN, RoHS:YU

EBO

FRU

See "Servicing Processors (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31037480.html#scrolltoc

7023515

Disk backplane assembly, 2 rear

EBO

FRU

See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40007ac1419009.html#scrolltoc

7027479

Disk backplane assembly, 4-Slot 3.5" RoHS:Y

EBO

FRU

See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40007ac1419009.html#scrolltoc

7044130

Power Supply, A258, 1000 Watt AC Input

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center_rotate

HS

CRU

See "Servicing Fan Modules (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091014194.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40000f91037409.html#scrolltoc

  3. See "Verifying InfiniBand Network Configuration".

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

7047503

Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y

DBO

CRU

See "Servicing Storage Drives and Rear Drives (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091011460.html#scrolltoc

7048864

Indicator assembly, left, 2U

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31014236.html#scrolltoc

7057184

Assembly, battery carrier remote

HS

FRU

"Replacing a Disk Controller BBU on a Database Server"

7058152

Assembly, motherboard, X4-2L

EBO

FRU

See "Servicing the Motherboard Assembly (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31037512.html#scrolltoc

7060020

Universal upgrade remote battery kit

EBO

FRU

"Replacing a Disk Controller BBU on a Database Server"

7069200

Assembly, 800 GB eMLC flash PCIe card

EBO

CRU

See "Servicing PCIe Cards (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40000f91037409.html#scrolltoc

7069242

CPU, E5-2630 v2, 6-core, 2.6 Ghz

EBO

FRU

See "Servicing Processors (FRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31037480.html#scrolltoc

7070656

Disk assembly, 1.2 TB, SAS2

HS

CRU

See "Servicing Storage Drives and Rear Drives (CRU)" in Sun Server X4-2L Service Manual at http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091011460.html#scrolltoc

A.7.8 Exadata Storage Server X3-2L Servers Parts

The following image shows the front view of Exadata Storage Server X3-2L Servers. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.

Figure A-35 Front View of Exadata Storage Server X3-2L Servers

Description of Figure A-35 follows
Description of "Figure A-35 Front View of Exadata Storage Server X3-2L Servers"

The following image shows the rear view of Exadata Storage Server X3-2L Servers.

Figure A-36 Rear View of Exadata Storage Server X3-2L Servers

Description of Figure A-36 follows
Description of "Figure A-36 Rear View of Exadata Storage Server X3-2L Servers"

The following table lists the replaceable parts for Exadata Storage Server X3-2L Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-53 Replacement Parts for Exadata Storage Server X3-2L Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

Battery, 3V, 390MAH, LITH, COIN

DBO

CRU

See "Servicing the Battery (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000f91037456.html#scrolltoc

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Attach Tool-less Slide-Rail Assemblies" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000671011466.html

371-4982

6 Gb SAS RAID PCI battery module (LiON), BBU-08, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/index.html

375-3696

InfiniBand (CX2) dual port CX2 4xQDR PCI-e

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000f91037409.html

375-3701

Assembly, 6 Gb SAS RAID disk PCIe HBA, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Powering Off Database Servers" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000f91037409.html

  3. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile
    

Note: Do not run any controller commands in the service manual when replacing the disk.

542-0428

Disk assembly, 600 GB, 15 K, SAS

HS

CRU

See "Servicing Storage Drives and Rear Drives (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091011460.html

7010036

3TB - 7200 RPM 3.5-inch SAS, disk assembly with bracket and disk

HS

CRU

See "Servicing Storage Drives and Rear Drives (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091011460.html

Note: Do not run any controller commands in the service manual when replacing the disk.

7014226

Cable, interlock, 125 mm

EBO

FRU

See "Servicing Cables (FRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/baecfjbc.html

7014391

Expander assembly, 2U

EBO

FRU

See "Servicing the SAS Expander Module (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/ceieidja.html

7017223

Indicator assembly, left

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules (FRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31014236.html

7017231

Indicator assembly, right

EBO

FRU

See "Servicing the Front LED/USB Indicator Modules (FRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31014236.html

7020486

DIMM, 8 GB, DDR3, 1600, 2Rx4, 1.35V

EBO

CRU

See "Servicing the DIMMs (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/ceicjagi.html

7020776

Heatsink, CPU, 2U, 60 MM FIN, RoHS:YU

EBO

FRU

See "Servicing Processors (FRU)" in Sun Server Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31037480.html

7023515

Disk backplane assembly, 2 rear

EBO

FRU

See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40007ac1419009.html

7026993

Assembly, 400 GB eMLC Flash PCIE card, with LP bracket

EBO

CRU

See "Servicing PCIe Cards (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000f91037409.html

7027479

Disk backplane assembly, 4-Slot 3.5" RoHS:Y

EBO

FRU

See "Servicing the Disk Backplane (FRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E22368_01/html/E27242/z40011771417642.html

7043559

CPU, E5-2630L, 2.0 G, 60 W, 6 C

EBO

FRU

See "Servicing Processors (FRU)" in Sun Server Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31037480.html

7044130

Power Supply, A258, 1000 Watt AC Input

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center_rotate

HS

CRU

See "Servicing Fan Modules (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091014194.html

7047257

Power supply, AC, A258 1000 Watt

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7049382

Assembly, motherboard tray

EBO

FRU

  1. See "Servicing the Motherboard Assembly (FRU)" in Sun Server X3-2L (formerly Sun Fire X4270 M3) Service Manual at http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31037512.html#scrolltoc

  2. Press F2 after restarting the server.

  3. Set the boot order.

7057184

Assembly, battery carrier remote

HS

FRU

"Replacing a Disk Controller BBU on a Database Server"

7060020

Universal upgrade remote battery kit

EBO

FRU

"Replacing a Disk Controller BBU on a Database Server"

A.7.9 Exadata Storage Server with Sun Fire X4270 M2 Servers Parts

The following image shows the front view of Exadata Storage Server with Sun Fire X4270 M2 Servers.

Figure A-37 Front View of Exadata Storage Server with Sun Fire X4270 M2 Servers

Description of Figure A-37 follows
Description of "Figure A-37 Front View of Exadata Storage Server with Sun Fire X4270 M2 Servers"
  1. Hard disk drives. The top drives are, from left to right, HDD2, HDD5, HDD8, and HDD11. The middle drives are, from left to right, HDD1, HDD4, HDD7, and HDD10. The bottom drives are, from left to right, HDD0, HDD3, HDD6, and HDD9.

The following image shows the rear view of Exadata Storage Server with Sun Fire X4270 M2 Servers.

Figure A-38 Rear View of Exadata Storage Server with Sun Fire X4270 M2 Servers

Description of Figure A-38 follows
Description of "Figure A-38 Rear View of Exadata Storage Server with Sun Fire X4270 M2 Servers"
  1. Power supplies.

  2. InfiniBand host channel adapter PCI Express module.

  3. Sun Flash Accelerator F20 PCIe Cards.

The following table lists the replaceable parts for Exadata Storage Server with Sun Fire X4270 M2 Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-54 Replacement Parts for Exadata Storage Server with Sun Fire X4270 M2 Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

Battery, 3V, 390MAH, LITH, COIN

EBO

CRU

See "Servicing the Server Battery" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/motherboard.html#50634787_71528

300-2235

Power supply, A249, 1200 W, 12 V, 2U, RoHS:Y

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50516002_11706

  3. Replace the CMA.

350-1502

Universal rack mount kit

EBO

CRU

  1. If the system is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "Installing the Server Into the Slide-Rail Assemblies" in Sun Fire X4170, X4270, and X4275 Servers Installation Guide at http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_74292

371-4415

24 GB solid state flash memory module; RoHS:Y

EBO

CRU

  1. See "Maintaining Flash Disks on Exadata Storage Servers".

  2. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  3. See "Servicing FMods" in Sun Flash Accelerator F20 PCIe Card User's Guide at http://docs.oracle.com/cd/E19682-01/E21358/z40002401421318.html

371-4650

Energy Storage Module (ESM) 5.5 v 11F capacitive backup power module, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "Servicing the ESM" in Sun Flash Accelerator F20 PCIe Card User's Guide at http://docs.oracle.com/cd/E19682-01/E21358/z40002401422152.html

  3. Reset the value for uptime using the following command:

    set clear_fault_action=true
    

371-4743

4 GB USB 2.0 flash drive, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "Servicing PCIe Cards" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_86021

  3. Do the following:

    a. Remove the system from the rack.

    b. Remove the top cover.

    c. Remove the F20 PCIe cards in slots 2 and 5, including the PCIe riser.

    d. Replace the USB flash drive next to the F20 card in PCIe slot 2.

    e. Restore the system by reversing steps a through d.

371-4887

2.26 GHz Intel 6-Core Xeon L5640, 12 MB, 60 W, RoHS:Y

EBO

FRU

See "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_23425

371-4965

LV DIMM, 4 GB, DDR3, 1RX4, 1333

EBO

CRU

See "Servicing Memory Modules (DIMMs)" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_71526

371-4982

6 Gb SAS RAID PCI battery module, RoHS:Y (LION), BBU-08

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/index.html

375-3696

InfiniBand (CX2) dual port CX2 4xQDR PCI-e

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "Servicing PCIe Cards" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_86021

375-3701

6 Gb SAS RAID disk PCIe HBA, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "Servicing PCIe Cards" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_86021

Note: Do not run any controller commands in the service manual when replacing the disk.

511-1500

F20 PCIe flash accelerator F20 SAS HBA, (non-populated) RoHS:Y

EBO

CRU

  1. See "Maintaining Flash Disks on Exadata Storage Servers".

  2. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  3. See "Servicing PCIe Cards" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_86021

  4. See "Servicing the Card" in Sun Flash Accelerator F20 PCIe Card User's Guide at http://docs.oracle.com/cd/E19682-01/E21358/z40002cc9112.html#scrolltoc

530-3927

Cable, PDB, MB, 1U+2U, ribbon

EBO

CRU

See "Servicing Cables" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_78576

530-4228

Cable, mini-SAS, 36 POS LONG, LY, RoHS:Y

EBO

CRU

See "Servicing Cables" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_78576

541-2075

Bus_bar, power, 1U+2U, RoHS:Y

EBO

FRU

See "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_71558

541-2884

Assembly, riser, X8, X8, 2U, PCI-E, RoHS:Y

EBO

CRU

See "Servicing PCIe Risers" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_53252

541-3310

Xeon Heatsink with grease, RoHS:Y,. 2U

EBO

FRU

See "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_23425

541-3356

x8/x8 switched PCIe riser assembly, RoHS:Y with the following:

  • x8/x8 switch PCIe riser

  • bracket

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "Servicing PCIe Risers" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_53252

541-4081

System board assembly, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Shutting Down Exadata Storage Server" for additional information.

  2. See "Servicing the Motherboard" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50516003_98526

541-4124

Fan deck, Hyde, RoHS:Y

EBO

FRU

See "Servicing the Fan Board" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_71556

541-4222

Assembly, fan, CR, 2U, RoHS:Y

HS

CRU

See "Servicing Fan Modules" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50516002_28930

541-4223

Power distribution board, 2U, RoHS:Y

EBO

FRU

See "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_71558

541-4304

Indicator, right, Hyde 12/24, ROHS:Y

EBO

FRU

See "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_71563

541-4305

Assembly, disk, SAS2, XP_DC, Hyde, RoHS:Y

EBO

FRU

See "Servicing the SAS Expander Board" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_28246

541-4306

Assembly, Connector board bracket, Hyde

EBO

FRU

See "Servicing the Connector Board" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_11100

541-4363

12-slot disk backplane, RoHS:Y

EBO

FRU

See "Servicing the Disk Backplane" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_71557

541-4371

Indicator, left, Hyde 12/24, RoHS:Y

EBO

FRU

See "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50515991_71563

542-0166

600GB - 15000 RPM SAS disk assembly with bracket and disk

HS

CRU

See "Servicing Storage Drives and Boot Drives" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50516002_61628

Note: Do not run any controller commands in the service manual when replacing the disk.

542-0247

2TB - 7200 RPM 3.5-inch SAS, disk assembly with bracket and disk

HS

CRU

See "Servicing Storage Drives and Boot Drives" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50516002_61628

Note: Do not run any controller commands in the service manual when replacing the disk.

560-2952

Cable kit, Hyde, RoHS:Y with the following:

  • Disk Backplane power cable

  • 24-slot DBP power cable

  • 12/24 slot Disk Backplane signal cable

  • Fan signal cable

  • Fan power cable

EBO

FRU

Refer to the entries for the individual items in the kit

7010036

3TB - 7200 RPM 3.5-inch SAS, disk assembly with bracket and disk

HS

CRU

See "Servicing Storage Drives and Boot Drives" in Sun Fire X4270 M2 Server Service Manual at http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50516002_61628

Note: Do not run any controller commands in the service manual when replacing the disk.

A.7.10 Exadata Storage Server with Sun Fire X4275 Servers Parts

The following figure shows the front view of Sun Fire X4275 Servers.

Figure A-39 Front View of Sun Fire X4275 Server

Description of Figure A-39 follows
Description of "Figure A-39 Front View of Sun Fire X4275 Server"
  1. Hard disk drives. The top drives are, from left to right, HDD2, HDD5, HDD8, and HDD11. The middle drives are, from left to right, HDD1, HDD4, HDD7, and HDD10. The bottom drives are, from left to right, HDD0, HDD3, HDD6, and HDD9.

The following figure shows the rear view of Sun Fire X4275 servers.

Figure A-40 Rear View of Sun Fire X4275 Server

Description of Figure A-40 follows
Description of "Figure A-40 Rear View of Sun Fire X4275 Server"

The following table lists the replaceable parts for Exadata Storage Server with Sun Fire X4275 Servers.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-55 Replacement Parts for Exadata Storage Server with Sun Fire X4275 Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

150-3993

Panasonic BR2032 battery, RoHS:Y for system board

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Battery" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1287052

300-1897

1050 watt power supply, RoHS:Y

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com/cd/E19477-01/820-5830-13/hotswap.html#50634786_pgfId-1098206

  3. Replace the CMA.

350-1502

Screw mount slide rail rackmount kit for Exadata Storage Server, RoHS:Y

EBO

FRU

  1. If the system is currently running, then it should be shut down gracefully.

  2. See "Attaching the Slide-Rail Assemblies to the Rack" in Sun Fire X4170, X4270, and X4275 Servers Installation Guide at http://docs.oracle.com//cd/E19477-01/820-5827-13/rack_install.html#50614309_28682

371-4288

4 GB registered DDR3-1333 DIMM, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing Memory Modules (DIMMs)" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1286176

371-4300

2.53GHz Quad-Core Intel Xeon E5540, 8MB, 80W, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing CPUs" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1287119

371-4415

24 GB solid state flash memory module; RoHS:Y

EBO

CRU

  1. See "Maintaining Flash Disks on Exadata Storage Servers".

  2. If the server is currently running, then it should be shut down gracefully.

  3. See "Servicing FMods" in Sun Flash Accelerator F20 PCIe Card User's Guide at http://docs.oracle.com/cd/E19682-01/E21358/z40002401421318.html

371-4650

Energy Storage Module (ESM) 5.5 v 11F capacitive backup power module, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the ESM" in Sun Flash Accelerator F20 PCIe Card User's Guide at http://docs.oracle.com/cd/E19682-01/E21358/z40002401422152.html

  3. Reset the value for uptime using the following command:

    set clear_fault_action=true
    

371-4743

4 GB USB 2.0 flash drive, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing PCIe Cards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1287272

  3. Do the following:

    1. Remove the system from the rack.

    2. Remove the top cover.

    3. Remove the F20 PCIe cards in slots 2 and 5, including the PCIe riser.

    4. Replace the USB flash drive under the F20 card next to PCIe slot 2.

    5. Restore the system by reversing steps a through d.

371-4746

Battery module, RoHS:Y for 6 Gb SAS RAID disk PCI, BBU-07

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See Sun Storage 6 Gb SAS PCIe RAID HBA, Internal Installation Guide For HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z at http://docs.oracle.com/cd/E19221-01/html/E22410/index.html

375-3606

Sun dual-port QDR (40 Gb/s) InfiniBand host channel adapter PCIe, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing PCIe Cards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1287272

375-3644

6 Gb SAS RAID disk PCIe HBA, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing PCIe Cards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1287272

511-1500

F20 PCIe flash accelerator F20 SAS HBA, (non-populated) RoHS:Y

EBO

CRU

  1. See "Maintaining Flash Disks on Exadata Storage Servers".

  2. If the server is currently running, then it should be shut down gracefully.

  3. See "Servicing PCIe Cards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1287272

  4. See "Servicing the Card" in Sun Flash Accelerator F20 PCIe Card User's Guide at http://docs.oracle.com/cd/E19682-01/E21358/z40002cc9112.html#scrolltoc

530-3892

4x Mini SAS/SATA cable, SFF-8087, 670mm, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing Cables" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_pgfId-1287782

530-3927

Power distribution board to system board cable, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Power Distribution Board" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1287132

530-4228

4x Mini SAS/SATA cable, SFF-8087, 690mm, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing Cables" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_pgfId-1287782

541-2073

Power distribution board/bus bar assembly, RoHS:Y with the following:

  • Bus bar left

  • Bus bar right

  • Horizontal power distribution bar

  • PDB signal cable

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Power Distribution Board" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1287132

541-2075

Bus_bar, power, 1U+2U, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Motherboard Assembly" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1287132

541-2542

System board assembly with tray, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Motherboard Assembly" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1287132

541-2884

x8/x8 PCIe riser assembly with the following:

  • x8/x8 PCIe riser, RoHS:Y

  • Bracket, RoHS:Y

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing PCIe Risers" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1286530

541-3290

CPU dual fan assembly with metal finger guards, 60x38 mm, 2U, RoHS:Y

HS

CRU

See "Servicing Fan Modules" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/hotswap.html#50634786_pgfId-1100474

541-3310

Xeon Heatsink with grease:RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing CPUs" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1287119

541-3356

x8/x8 switched PCIe riser assembly, RoHS:Y with the following:

  • x8/x8 switch PCIe riser

  • bracket

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing PCIe Risers" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/motherboard.html#50634787_pgfId-1286530

541-3385

Connector board assembly with the following:

  • Mounting bracket, RoHS:Y

  • Connector board, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Connector Break Out Board" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1287220

541-3386

12-slot disk backplane, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Storage Drive Backplane" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1286916

541-3387

SAS expander card assembly, RoHS:Y with the following:

  • Bracket, RoHS:Y

  • SAS expander board, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Storage Disk Expander Card" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1286818

541-3388

Left indicator assembly, RoHS:Y with the following:

  • Left bracket, RoHS:Y

  • Left LED board, RoHS:Y

  • Indicator cable, RoHS:Y

EBO

FRU

  1. If the system is currently running, then it should be shut down gracefully.

  2. See "Servicing the Front Control Panel Light Pipe Assembly" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_pgfId-1287263

541-3389

Right indicator assembly, RoHS:Y with the following:

  • Right bracket, RoHS:Y

  • Right LED board, RoHS:Y

  • Indicator cable, RoHS:Y

EBO

FRU

  1. If the system is currently running, then it should be shut down gracefully.

  2. See "Servicing the Front Control Panel Light Pipe Assembly" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_pgfId-1287263

541-3394

Fan board assembly with the following:

  • Top bracket, RoHS:Y

  • Bottom bracket, RoHS:Y

  • Fan board, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Fan Power Boards" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4170_x4270.html#50634783_pgfId-1286820

542-0166

600 GB 15 K RPM SAS disk assembly, RoHS:Y with bracket and disk

HS

CRU

  1. See "Maintaining the Hard Disks of Exadata Storage Servers"

  2. See "Servicing Storage Drives" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/hotswap.html#50634786_pgfId-1093656

Note: Do not run any controller commands in the service manual when replacing the disk.

542-0167

2 TB 7.2 K RPM 3.5-inch SATA disk assembly, RoHS:Y with bracket and disk

HS

CRU

See "Servicing Storage Drives" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/hotswap.html#50634786_pgfId-1093656

Note: Do not run any controller commands in the service manual when replacing the disk.

560-2937

Exadata Storage Server cable kit with the following:

  • 10-pin backplane power cable, RoHS:Y

  • 20-pin backplane 12C cable, RoHS:Y

  • 6-pin fan power cable, RoHS:Y

  • 16-pin FAN 12C cable, RoHS:Y

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Servicing the Connector Break Out Board" in Sun Fire X4170, X4270, and X4275 Servers Service Manual at http://docs.oracle.com//cd/E19477-01/820-5830-13/infrastructure_x4275.html#50634784_pgfId-1287220+6

A.8 Parts for InfiniBand Switches

The following table lists the replaceable parts for the InfiniBand switches used with Oracle Exadata Rack. See "Cables and Cable Accessories for Oracle Exadata Rack" for information about InfiniBand cables.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-56 Replacement Parts for InfiniBand Switches

Part Number Description Repair Category Coverage with Basic Warranty Repair

300-2143

760 watt power supply, RoHS:Y

HS

CRU

See "Servicing Power Supplies" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z400000e1496507.html

300-2299

760 watt AC input power supply

HS

CRU

See "Servicing Power Supplies" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z400000e1496507.html

350-1312

Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y

HS

CRU

See "Servicing Fans" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z400000e1499116.html

350-1566

Fan module, 1 RU, Sanace, reverse

HS

CRU

See "Servicing Fans" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z400000e1499116.html

371-2210

CR2032 3 v battery, RoHS:Y

IR

CRU

See "Servicing the Battery" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/cggefcei.html

541-3495

Sun Datacenter InfiniBand Switch 36, RoHS:YL

IR

CRU

  1. See "Replacing a Failed Sun Datacenter InfiniBand Switch 36 Switch"

  2. See "Servicing the Switch" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z40000609112.html

7052970

Sun Datacenter InfiniBand Switch 36, RoHS:YL

IR

CRU

  1. See "Replacing a Failed Sun Datacenter InfiniBand Switch 36 Switch"

  2. See "Servicing the Switch" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z40000609112.html

7061031

Fan module, 1 RU, Sanace, reverse

HS

CRU

See "Servicing Fans" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z400000e1499116.html

7065505

Power supply, AC, A247B, 12V, 760W, FW2022

HS

FRU

See "Servicing Power Supplies" in Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/z400000e1496507.html

A.9 Parts for Cisco Switch

The following table lists replaceable parts for the Cisco switch used with Oracle Exadata Rack.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-57 Replacement Parts for Cisco Switch

Part Number Description Repair Category Coverage with Basic Warranty Repair

7023685

Cisco Catalyst 4948 switch, RoHS:Y

IR

CRU

See "Installing the Switch" in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins/03instal.html

7024423

Power supply for Cisco Catalyst 4948 switch, RoHS:Y

HS

CRU

See "Removal and Replacement Procedures" in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins/04frus.html

7024424

Cooling fan for Cisco Catalyst 4948 switch, RoHS:Y

HS

CRU

See "Removing and Installing the Fan Tray" in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins/04frus.html

A.10 Parts for KVM Switch and KMM Tray

The following table lists the replacement parts for the KVM switch and KMM tray.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-58 Replacement Parts for KVM/KMM

Part Number Description Repair Category Coverage with Basic Warranty Repair

371-4778

Assembly, KMM, with Japanese keyboard and mouse module

IR

CRU

See the Installation chapter in Avocent MergePoint Unity Switch Installer/User Guide at http://pcs.mktg.avocent.com/@@content/manual/590883501c.pdf

371-4779

Avocent MPU4032DAC-001 32-port KVM switch, RoHS:Y

IR

CRU

See the Installation chapter in Avocent MergePoint Unity Switch Installer/User Guide at http://pcs.mktg.avocent.com/@@content/manual/590883501c.pdf

371-4780

Avocent KMM drawer with United States keyboard, RoHS:Y

IR

CRU

See the Installation chapter in Avocent MergePoint Unity Switch Installer/User Guide at http://pcs.mktg.avocent.com/@@content/manual/590883501c.pdf

371-4781

Avocent (DSRIQ-USB) DB 15 M to RJ45/USB KVM adapter, RoHS:Y

IR

CRU

See the Installation chapter in Avocent MergePoint Unity Switch Installer/User Guide at http://pcs.mktg.avocent.com/@@content/manual/590883501c.pdf

A.11 Parts for Power Distribution Units

The following table lists the replacement parts for the power distribution units (PDUs). Given the number of cables and connections, Oracle recommends the Oracle Exadata Rack rack be shut down when replacing power distribution unit parts.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-59 Replacement Parts for Power Distribution Units

Part Number Description Repair Category Coverage with Basic Warranty Repair

180-2379

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y

HS

CRU

Not applicable

180-2380

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y

HS

CRU

Not applicable

371-4000

Three-phase PDU: 15kV,5-Pin, IEC309 32A, 5 PIN 230/400V, 3ph IP44, International, RoHS:Y

IR

FRU

See "Replacing a Power Distribution Unit"

371-4001

Three-phase PDU; 24 kVA, high voltage for Oracle Exadata Database Machine X2-8 Full Rack

IR

FRU

See "Replacing a Power Distribution Unit"

371-4199

Single-phase PDU: 15kVA, with three 30A/250V 2-Pole/3-Wire NEMA L6-30P Plugs, North America, RoHS:Y

IR

FRU

See "Replacing a Power Distribution Unit"

371-4201

Single-phase PDU: 15kVA, with three Blue 32A/240V Splashproof 2-Pole/3-Wire IEC 60309 Plugs, International, RoHS:Y

IR

FRU

See "Replacing a Power Distribution Unit"

371-5039

Single-phase PDU: 22k VA Hubbell CS8265C PlugNo X-Option

IR

FRU

See "Replacing a Power Distribution Unit"

371-5040

Single-phase PDU: 22k VA Blue 32A IEC 60309 Plug No X-Option

IR

FRU

See "Replacing a Power Distribution Unit".

371-4510

Three-phase PDU; 24 kVA, low voltage for Oracle Exadata Database Machine X2-8 Full Rack

IR

FRU

See "Replacing a Power Distribution Unit"

7051908

Three-phase PDU: 15kVA, IEC309 60A, 4 PIN, 250VAC, 3ph IP67, North America, RoHS:Y

IR

FRU

See "Replacing a Power Distribution Unit"

7078660

Three-phase PDU: 37kVA, RMII, low voltage

IR

FRU

See "Replacing a Power Distribution Unit"

7078664

Three-phase PDU: 37kVA, RMII, high voltage

IR

FRU

See "Replacing a Power Distribution Unit"

A.12 Cables and Cable Accessories for Oracle Exadata Rack

The following table lists the replacement cables and cable accessories for Oracle Exadata Rack.

Note:

All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table A-60 Replacement Cables for Oracle Exadata Rack

Part Number Description Repair Category Coverage with Basic Warranty Repair

350-1287

Slim rail, CMA, 1U-2U for Exadata Storage Server

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Installing the Cable Management Arm" in Sun Fire X4170, X4270, and X4275 Servers Installation Manual at http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_99582

350-1519

Serial cable kit, RoHS:Y with the following:

  • USB to DB 9-pin M serial cable

  • DB 9-pin F to DB 9-pin F null modem cable

HS

CRU

See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

350-1546

Cable management arm (CMA) 1U, RoHS:Y for database server

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Installing the Cable Management Arm" in Sun Fire X4170, X4270, and X4275 Servers Installation Manual at http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_99582

350-1637

Label assembly, EV2, 2-way, upgrade, label

HS

CRU

See Oracle Exadata Database Machine System Overview

350-1638

Label assembly EV2, 3-way, service upgrade, label

HS

CRU

See Oracle Exadata Database Machine System Overview

350-1639

Label assembly EV2, 4-way, service upgrade, label

HS

CRU

See Oracle Exadata Database Machine System Overview

350-1640

Label assembly EV2, 5-way, service upgrade, label

HS

CRU

See Oracle Exadata Database Machine System Overview

350-1641

Label assembly EV2, 6-way, service upgrade, label

HS

CRU

See Oracle Exadata Database Machine System Overview

350-1642

Label assembly EV2, 7-way, service upgrade, label

HS

CRU

See Oracle Exadata Database Machine System Overview

350-1643

Label assembly EV2, 8-way, service upgrade, label

HS

CRU

See Oracle Exadata Database Machine System Overview

530-4445

QSFP InfiniBand passive copper cable, 10 GbE, 3 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

Note: There is a loss of redundancy when replacing cables.

530-4446

QSFP InfiniBand passive copper cable, 10 GbE, 5 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

Note: There is a loss of redundancy when replacing cables.

530-4403

4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

Note: There is a loss of redundancy when replacing cables.

530-4404

4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

530-4415

4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

530-4432

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4433

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4434

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4435

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4436

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4437

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4438

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4444

QSFP to QSFP Passive Copper Cable, 1 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

530-4445

QSFP passive copper cable, 10 GE, 3 m

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

530-4502

Ethernet cable, Cat 5/5E, 10 foot, blue, RoHS:Y

HS

CRU

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

7015400

Power cable, jumper, SR2, 2m C14RA, 10A, C13

HS

CRU

See "Replacing a Power Distribution Unit".

7042273

Slim rail, cable management arm, 1U-2U for Exadata Storage Server

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully.

  2. See "Installing the Cable Management Arm" in Sun Fire X4170, X4270, and X4275 Servers Installation Manual at http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_99582

7102869

Passive fiber InfiniBand cable, 10 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

Note: Purchase 2 QSFP SR Transceiver (Part Number X2124A-N) for each passive fiber cable.

7102870

Passive fiber InfiniBand cable, 20 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

Note: Purchase 2 QSFP SR Transceiver (Part Number X2124A-N) for each passive fiber cable.

7102871

Passive fiber InfiniBand cable, 50 m, RoHS:Y

HS

CRU

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

  2. Verify the InfiniBand network configuration.

Note: Purchase 2 QSFP SR Transceiver (Part Number X2124A-N) for each passive fiber cable.