Alarm Synchronization Configuration

You turn on alarm synchronization in the system configuration.

To use alarm synchronization:

  1. In Superuser mode, type configure terminal and press Enter.
    ORACLE# configure terminal
    ORACLE(configure)#
  2. Type system and press Enter.
    ORACLE(configure)# system
    ORACLE(system)#
  3. Type system-config and press Enter.
    ORACLE(system)# system-config
    ORACLE(system-config)#
  4. trap-event-lifetime—To enable alarm synchronization—and cause the Oracle® Enterprise Session Border Controller to record trap information in the apSysMgmtTrapTable and the apSysMgmtTrapInformationTable—set this parameter to the number of days you want to keep the information. Leaving this parameter set to 0 (default) turns alarm synchronization off, and you can keep information in the tables for up to 7 days. 7 is the maximum value for this parameter.