Operation Type and Location

The following parameters determine the physical interface card and port you are about to configure.

Set the following parameters to configure the operation type and location for a physical interface:

  1. operation-type—Select the type of physical interface connection to use. The default value is control. The valid values are:
    • media—Front-panel interfaces only. Port: 0-3; Slot: 0 or 1

    • maintenance—Rear-panel interface only. Port: 0, 1, or 2; Slot: 0

    • control—Rear-panel interfaces only. Port 0, 1, or 2; Slot: 0

  2. slot—Select the physical slot number on the Oracle® Enterprise Session Border Controller chassis. The default is 0. The valid values are:
    • 0 is the motherboard (rear-panel interface) if the name begins with wancom

    • 0 is the left two media Phy media slot on front of the Oracle® Enterprise Session Border Controller Chassis

    • 1 is the right Phy media slot on front of the Oracle® Enterprise Session Border Controller Chassis (front and rear interfaces)

  3. port—Set the port. From left to right as you face the chassis, the possible values are:
    • 0-3—For four possible GigE ports on the front of the Oracle® Enterprise Session Border Controller chassis

    • 0-3—For four possible FastE ports on the front of the Oracle® Enterprise Session Border Controller chassis

    • 0-2—Rear interfaces