Analytics > Designing an Analysis > Step 2: Creating Layouts > Showing Results in Scrolling Tickers
Showing Results in Scrolling Tickers
A ticker displays the results of a report as a marquee (moving results that scroll across the page). You can customize the size of the scroll area, the speed and direction in which the results scroll, and other display settings.
NOTE: If your Web browser does not support moving text, the results will appear, but they will not scroll across the page.
To add or modify a Ticker view
- In the Create Layout page, perform one of the following actions:
- To generate default settings for the most commonly used fields, click the Set Defaults button.
CAUTION: If you click the Set Defaults button after entering values in other fields, your entered values are cleared.
- To clear all fields, click the Clear Fields button.
NOTE: After you clear all fields, you can click the Set Default button to restore default settings for the most commonly used fields.
- Make your selections for the fields in the workspace.
The following table describes the fields.
Ticker View Workspace Field
|
Description
|
Behavior
|
Specifies how the results move in the ticker:
Scroll. The results start hidden, scroll on to the page, then off the page before repeating.
Slide. The results start hidden, scroll on to the page, then stop once touching the other side.
Alternate. The results bounce back and forward inside the marquee.
|
Direction
|
Specifies the direction the results move in the ticker (Left, Right, Down, or Up).
|
Width
|
Specifies the width of the ticker, either in pixels, or as a percentage of the page width.
For example, a value of 200 indicates a width of 200 pixels, and a value of 25% indicates a width of one-quarter of the page.
|
Height
|
Specifies the height of the ticker, either in pixels, or as a percentage of the page height.
For example, a value of 200 indicates a height of 200 pixels, and a value of 25% indicates a height of one-quarter of the page.
|
Beginning Text
|
Specifies any optional text or graphics to display at the beginning of each redraw of the results. You can use HTML to format the text.
If you include an image, make sure you know where the image is located. If the image is for your use only, the following is a sample location:
c:\mycomputer\temp\report.gif
If the image is for use in a shared environment or web site, it must be located on a network drive accessible to all users. For a shared image, specify the UNC name, for example:
\\ALLUSERS\graphics\report.gif
|
Row Format
|
Specifies the HTML to use in formatting the rows in the results.
To include the results from a designated column, use @n. For example, @1 inserts the results from the first column, and @3 inserts the results of the third column.
|
Row Separator
|
Specifies the character that separates one row from another.
|
Column Separator
|
Specifies the character that separates one column from another. This is used when Row Format is blank, which results in all columns being displayed.
|
Ending Text
|
Specifies any optional text or graphics to display at the end of each redraw of the results. You can use HTML to format the text.
If you include an image, make sure you know where the image is located. If the image is for your use only, the following is a sample location:
c:\mycomputer\temp\report.gif
If the image is for use in a shared environment or web site, it must be located on a network drive accessible to all users. For a shared image, specify the UNC name, for example:
\\ALLUSERS\graphics\report.gif
|
NOTE: Several of these fields are pre-populated with HTML that provides initial formatting. Take care when editing this text, so that the original HTML is still valid. If you remove the HTML from one of the fields, you should remove it from the others, too, otherwise the ticker will not function correctly.
- To specify additional options, perform the following actions:
- Click the Advanced button.
The Advanced Ticker Options dialog box appears.
- Make your selections for the advanced options and click OK.
The following table describes the advanced options.
Advanced Options in the Ticker View Workspace
|
Description
|
# of Loops
|
Specifies the number of times that the results will scroll. The default is an infinite number of times.
You must specify a whole number.
|
Scroll Amount
|
Sets the number of pixels between successive redraws of the results. Larger values cause faster, less smooth scrolling.
|
Scroll Delay
|
Specifies the number of milliseconds between successive redraws of the results. Large values cause slower scrolling.
|
Background Color
|
Specifies the color to use for the background. Depending on what your browser supports, you can enter a color name such as yellow or blue, or use the 6-digit hexadecimal format, such as #AFEEEE for pale turquoise. (You can omit the number sign character from the hexadecimal format.)
|
Additional Marquee Attributes
|
Specifies other marquee options that your browser may support, such as ALIGN="top | middle | bottom” to align the ticker to the top, middle or bottom of the text around it. You can also add HTML to further customize the look of the ticker.
|
- Select the Display Results check box to preview the ticker view.
- Click OK to return to the Layout Views page.
- To move or edit the ticker view (and other views, as required) on the page, do the following:
- To move the view to a different location on the page, drag the view, and drop it in the new location.
- To format the appearance of the ticker view, click the Format View button for the view.
You can specify Cell, Border, Background, and Additional Formatting Options (Width, Height, Indent, Right Padding, Top Padding, Bottom Padding).
- To edit the ticker view, click the Edit View button for the view.
- To delete the ticker view, click the Delete View button for the view.
- When you finish making your changes, save the report.
|