Configure PDF/X output by setting the properties described below. The values that you set for these properties will depend on the printing device.
Note the following restrictions on other PDF properties:
pdf-version
— value above 1.4 is not allowed for PDF/X-1a output
pdf-security
— must be set to False
pdf-encryption-level
— must be set to 0
pdf-font-embedding
— must be set to true
For more information on PDF/X output, see Generating PDF/A and PDF/X Output in Report Designer's Guide for Oracle Business Intelligence Publisher.
Property Name | Description |
---|---|
PDF/X ICC Profile Data |
Default: None Description: (Required) The name of the ICC profile data file, for example: CoatedFOGRA27.icc. The ICC (International Color Consortium) profile is a binary file describing the color characteristics of the intended output device. (For more information, see the article at http://en.wikipedia.org/wiki/ICC_profile). For production environments, the color profile may be provided by your print vendor or by the printing company that prints the generated PDF/X file. The file must be placed under Profile data is also available from Adobe (http://www.adobe.com/support) or colormanagement.org (http://www.colormanagement.org/). Internal Name: |
PDF/X output condition identifier |
Default: None Description: (Required) The name of one of the standard printing conditions registered with ICC (International Color Consortium). The list of standard CMYK printing conditions to use with PDF/X-1a is provided on the following ICC website: http://www.color.org/chardata/drsection1.xalter. The value that you enter for this property is a valid "Reference name," for example: FOGRA43. Choose the appropriate value for the intended printing environment. This name is often used to guide automatic processing of the file by the consumer of the PDF/X document, or to inform the default settings in interactive applications. Internal Name: |
PDF/X output condition |
Default: None Description: A string describing the intended printing condition in a form that will be meaningful to a human operator at the site receiving the exchanged file. The value is set in OutputCondition field of OutputIntents dictionary. Internal Name: |
PDF/X registry name |
Default: http://www.color.org Description: A registry name. Set this property when the Internal Name: |
PDF/X version |
Default: PDF/X-1a:2003 Description: The PDF/X version set in GTS_PDFXVersion and GTS_PDFXConformance fields of Info dictionary. PDF/X-1a:2003 is the only value currently supported. Internal Name: |