VstpTxM3RLInvalidDPC

Measurement Group
VSTP MTP3 Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of ingress messages M3RL discarded because the DPC was not the True Point Code (TPC) or Capability Point Code (CPC) configured for the vSTP.
Collection Interval
5 min
Peg Condition
Each time a message is discarded because the message is pegged each time DPC is not the true point code
Measurement Scope
Site

Recovery

This value provides a measure of how many ingress messages M3RL are discarded because the DPC was not the True Point Code (TPC) or Capability Point Code (CPC) configured for the vSTP. If this measurement is large, it may indicate a routing inconsistency between STP/SG and the vSTP.