This message indicates that a ported out subscriber is fraudulently attempted to send SMS using the old networks SMSC. An error message was generated and returned to the originating MSC.
Example
RLGHNCXA21W 02-07-21 16:20:19 EST EAGLE 37.5.0 0018.1129 CARD 1103,A INFO Ported subs SMSC matches Home SMSC Addr SIO=03 OPC=001-001-001 DPC=002-002-002 SCCP MSG TYPE=04 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=250 NP=04 NAI=010 ADDR=123456789012345678901 PC=003-003-003 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345678901234567890 PC=001-001-001 SSN=004 LSN=ABCD123 GTTSET=3 203 46 Report Date:02-07-21 Time:16:20:19This alternate output includes the redirected destination and is used when a redirected MSU encounters an error.
RLGHNCXA21W 02-07-21 16:20:19 EST EAGLE 37.5.0 0018.1129 CARD 1103,A INFO Ported subs SMSC matches Home SMSC Addr SIO=03 OPC=001-001-001 DPC=002-002-002 SCCP MSG TYPE=04 GTT on CdPA used MOSMSGTA=9193802053 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=250 NP=04 NAI=010 ADDR=123456789012345678901 PC=003-003-003 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345678901234567890 PC=001-001-001 SSN=004 LSN=ABCD123 GTTSET=3 203 46 Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.