Required Host Firmware

Oracle 6.4 TB NVMe SSD v2s run with the minimum required host firmware listed in the following table.

x86 Driver
Minimum Required Host Firmware Version (Patch No.)
Recommended System Firmware Version (Patch No.)
Oracle Server X8-2
Patch 29626005: Oracle Server X8-2 SW 1.0.0
Patch 30785622: Oracle Server X8-2 SW 1.2.0 - FIRMWARE PACK or later
Oracle Server X8-2L
Patch 29626012: Oracle Server X8-2L SW 1.0.0
Patch 30785633: Oracle Server X8-2L SW 1.2.0 - FIRMWARE PACK or later
Oracle Server X7-2
Patch 29001726: Oracle Server X7-2 SW 1.3.3
Patch 30696356: Oracle Server X7-2 SW 1.7.0 - FIRMWARE PACK or later
Oracle Server X7-2L
Patch 29001781: Oracle Server X7-2L SW 1.3.3
Patch 30696375: Oracle Server X7-2L SW 1.7.0 - FIRMWARE PACK or later
SPARC Driver
Minimum Required System Firmware Version (Patch No.)
Recommended System Firmware Version (Patch No.)
SPARC S7-2 Server
Patch 28902041: FIRMWARE: SPARC S7-2 SUN SYSTEM FIRMWARE 9.9.1.F

With Hardware_Programmables-1.0.14-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

Patch 30673926: FIRMWARE: SPARC S7-2 SUN SYSTEM FIRMWARE 9.9.3 or later

With Hardware_Programmables-1.0.14-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

SPARC S7-2L Server
Patch 28902042: FIRMWARE: SPARC S7-2L SUN SYSTEM FIRMWARE 9.9.1.F

With Hardware_Programmables-1.0.14-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

Patch 30673926: FIRMWARE: SPARC S7-2 SUN SYSTEM FIRMWARE 9.9.3 or later

With Hardware_Programmables-1.0.14-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

SPARC T7-1 Server
Patch 28902035: FIRMWARE: SPARC T7-1 SUN SYSTEM FIRMWARE 9.9.1.F

With Hardware_Programmables-1.0.17-SPARC_T7-1.pkg file also installed.

Patch 30673922: FIRMWARE: SPARC T7-1 SUN SYSTEM FIRMWARE 9.9.3 or later

With Hardware_Programmables-1.0.17-SPARC_T7-1.pkg file also installed.

SPARC T7-2 Server
Patch 28902036: FIRMWARE: SPARC T7-2 SUN SYSTEM FIRMWARE 9.9.1.F

With Hardware_Programmables-1.0.15-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

Patch 30673924: FIRMWARE: SPARC T7-2 SUN SYSTEM FIRMWARE 9.9.3 or later

With Hardware_Programmables-1.0.15-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

SPARC T7-4 Server
Patch 28902039: FIRMWARE: SPARC T7-4 SUN SYSTEM FIRMWARE 9.9.1.F

With Hardware_Programmables-1.0.14-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

Patch 30673925: FIRMWARE: SPARC T7-4 SUN SYSTEM FIRMWARE 9.9.3 or later

With Hardware_Programmables-1.0.14-SPARC_T7-1+T7-2+T7-4+S7-2+S7-2L.pkg file also installed.

SPARC T8-1 Server
Patch 28902029: FIRMWARE: SPARC T8-1 SUN SYSTEM FIRMWARE 9.9.1.F

With Hardware_Programmables-1.0.17-SPARC_T8-1.pkg file also installed.

Patch 30673919: FIRMWARE: SPARC T8-1 SUN SYSTEM FIRMWARE 9.9.3 or later

With Hardware_Programmables-1.0.17-SPARC_T8-1.pkg file also installed.

SPARC T8-2 Server
Patch 28902030: FIRMWARE: SPARC T8-2 SUN SYSTEM FIRMWARE 9.9.1.F
Patch 30673920: FIRMWARE: SPARC T8-2 SUN SYSTEM FIRMWARE 9.9.3 or later
SPARC T8-4 Server
Patch 28902031: FIRMWARE: SPARC T8-4 SUN SYSTEM FIRMWARE 9.9.1.F