8013 - MpNgnPsStateMismatch

Alarm Group
DIAM
Description
DA-MP NGN-PS administrative and operational state mismatch.
Severity
Major
Instance
<DA-MP Name>
HA Score
Normal
Auto Clear Seconds
0 (zero)
OID
eagleXgDiameterMpNgnPsStateMismatch

Recovery

  1. This alarm is potentially caused when a DA-MP restart is required.

    The alarm clears when the administrative and operational states are aligned.

  2. If the NGN-PS feature is mistakenly activated, disable the feature to clear the alarm and align the operational state with administrative state .
  3. If the NGN-PS feature is mistakenly de-activated, enable the feature to clear the alarm and align the operational state with administrative state.