10073 - Server Group Max Allowed HA Role Warning

Alarm Group:
HA
Description:
The server group has received the maximum number of allowed HA role warnings.
Severity:
Minor
Instance:
Affected Server Group name
HA Score:
Normal
Auto Clear Seconds:
0
OID:
oAGTSgMaxAllowedHARoleWarnNotify

Recovery:

  1. Log into the SO GUI and navigate to the HA page (Status & Manage > HA).
  2. Click the Edit button and change the Max Allowed HA role of the current Standby SOAM to Active.
  3. If you cannot perform the HA switchover, log into the server (Status & Manage > Server).
  4. Select the Active server and click Restart to restart the server.
    HA switchover occurs.
  5. Verify the switchover was successful from the Active SOAM GUI, or login to the Active and Standby SOAMs and execute this command:
    # ha.mystate