Go to primary content
Diameter Signaling Router Alarms and KPIs
Release 8.2
E89015-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

22501 - DSR Application Degraded

Alarm Group:
APPL
Description:
Unable to forward requests to the DSR application because it is degraded.
Severity:
Major
Instance:
<DSR Application Name>

Note:

The value for DSR Application Name varies depending on the DSR application generating the alarm (DCA, PCA, FABR, Policy DRA, RBAR, etc.). Use the name that corresponds to the specific DSR application in use.
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
eagleXgDiameterDsrApplicationDegradedNotify

Recovery:

  1. Display and monitor the DSR application status by navigating to Diameter > Maintenance > Applications in the SO GUI. Verify the Admin State is set as expected.
  2. A DSR application becomes degraded when the DSR application becomes congested, if enabled.

    Note:

    This alarm is NOT raised when the DSR application is shutting down gracefully or application is in the disabled state. Only the DSR application operational status is changed to unavailable.
  3. Check the Event History logs for additional DIAM events or alarms for this MP server.
  4. If the problem persists, it is recommended to contact My Oracle Support (MOS).