22718 - Binding Not Found for Binding Dependent Session Initiate Request

Event Group:
PCA
Description:
Binding record is not found for the configured binding keys in the binding dependent session-initiation request message.
Severity:
Info
Instance:
N/A
HA Score:
Normal
Throttle Seconds:
60
OID:
pdraPdraBindingRecordNotFoundNotify

Recovery:

  1. Check the Policy and Charging GUI Main Menu Policy and Charging > Configuration > Binding Key Priority on the subscriber key priorities to ensure the configuration is correct.
  2. Using the Binding Key Query Tool, check if a binding exists for the binding keys at Policy DRA > Configuration > Binding Key Priority.