Go to primary content
Tekelec Platform Gateway Location Application (GLA)
Release 8.2
E89011
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

Configure GLA Exceptions elements

This table describes the elements for configuring GLA error exceptions:

Table 4-1 Configure GLA Exception Elements

Element Description Data Input Notes
Action The action to be taken when encountering the specific error.

Format: Options

Range:

  • Discard - Request is discarded and no answer is sent
  • Answer with Result Code - a Diameter Answer message with the Result-Code AVP is sent to Request's Origin-Host.
  • Answer with Experimental Result Code - Diameter Answer message with an Experimental-Result AVP is sent to Request's Origin-Host Answer with Experimental Result Code
Result Code

The value displayed in the message if the Action is Answer with Result Code or Answer with Experimental Result Code.

Select a Result Code from the listing provided or enter a specific code.

Format: List

Range: 1000-5999

Vendor ID The vendor ID displayed in the Experimental-Result pair if the Action is Answer with Experimental Result Code.

Format: Text box

Range: 1 - 4294967295

Error String The text string appended to the Error-Message AVP.

Format: Text box

Range: 0 to 64 characters