Number of Request messages received without a Routing Entity Address AVP.
Collection Interval
5 min
Peg Condition
For each routing exception with no valid User Identity address found and the number of AVPs searched for the message was 0.
Measurement Scope
Server Group
Recovery
If this event is considered abnormal, then use validate which AVPs are configured for routing with the Application ID and Command Code using the FABR GUI screen.