Go to primary content
Diameter Signaling Router Measurements
Release 8.2
E89016
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

Error Code 305

Associated Error Category
Policy DRA Unavailable or Degraded
Description
Policy DRA Degraded
Associated P-DRA Alarm/Event
Alarm 22501 - DSR Application Degraded (refer to the DSR Alarms and KPIs Reference for details about this alarm)
Associated Measurement
RxApplUnavailableForRequest
Associated Diameter Interface / Message Type
  • All Gx requests
  • All Rx Requests
  • All Gx-Prime Requests
GUI Configurable
Yes

Recovery

  1. Go to the P-DRA SOAM GUI at Main Menu > Diameter > Maintenance > Applications to verify Policy DRA's admin state is set as expected.
  2. Check the Main Menu > Diameter > Maintenance > Applications to verify Policy DRA's Operational Status and Congestion Level. Policy DRA's Operational Status is "Unavailable" when the operator has removed Policy DRA from service (Admin State is "Disabled").
  3. Check Main Menu > Alarms & Events > View History for relevant events or alarms related to this DA-MP server.
  4. Get the measurement report from Main Menu > Measurements > Report for, but not limited to, measurement RxApplUnavailableForAnswer.