EvMdIwfTransSuccessByDiamExtNode

Measurement ID
15957
Measurement Group
MD-IWF Performance
Measurement Type
Simple
Measurement Dimension
Single
Description
Number of transactions where Diameter external node sends success (2xxx) Answer to DSR, and MD-IWF sends success response to SS7
Collection Interval
5 min
Peg Condition
This measurement is pegged when a Diameter external node sends a success (2xxx) Answer to DSR, which is then forwarded by DM-IWF (on DA-MP) to MD-IWF (on SS7-MP), and MD-IWF in turn sends a success response (not an Abort or Reject) to the SS7 network.
Measurement Scope
Site

Recovery

  1. No action required