RxPcaNgnPsDrop

Measurement ID
11462
Measurement Group
PCA NGN-PS Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of PCA ingress NGN-PS messages discarded or rejected.
Collection Interval
5 min
Peg Condition
This measurement is pegged each time PCA discards or rejects an NGN-PS message.
Measurement Scope
All

Recovery

  1. This measurement indicates that a DA-MP may be experiencing congestion. Additional processing capacity at the PCA DA-MP may be needed.