71414 – SCTP Path Status Changed

Alarm Type
PCRF
Description
SCTP Path Status Changed. Occurs when an MPE or MRA device is multihoming. The alarm occurs when one path fails, and clears when the path becomes available again. If the path that is currently transmitting Diameter messages fails, the alarm is triggered when the SCTP association tries to send the next Diameter message. If the path is not transmitting Diameter messages (it is a backup) then it may take up to 30 seconds for the alarm to be triggered, since heartbeat chunks are sent every 30 seconds.
Default Severity
Minor
Instance
Peer address + Association ID
HA Score
Normal
Clearing Action
This alarm clears automatically after 7200 seconds (2 hours).
OID
SctpPathStatusChanged

Recovery:

If the problem persists, contact My Oracle Support (MOS).