Configuring Log Settings

Note: While all CMP users can view debug log settings, only users with the Administrator user role can configure debug logs.
Note: The MPE device does not support SMSR (SMS Relay) Log configuration.
To configure per class log settings for a component:
  1. From the appropriate (Policy Server or MRA section of the navigation pane, select Configuration.

    The content tree displays a list of policy device groups; the initial group is ALL.

  2. From the content tree, select the policy device.

    The device's Administration page opens in the work area.

  3. Select the Debug tab.

    The device Administration page shows the configuration settings for supported components (for example, Tomcat Log, RC Log, SMSR Log, or MRA log).

  4. Click Modify.

    The device's Administration page becomes editable.

  5. In the specific Log Configuration section (for example, Tomcat Log, RC Log, SMSR Log, or MRA log) enter a value if you want to override the defaultScan Period (seconds).

    The default value is 20 seconds.
    Note: The MRA device does not support SMSR (SMS Relay) Log configuration.

  6. To override the default value, select the Root Log Level from the list.

    Available options are:
    • Off—Turns off logging.
    • Error—Designates error events which may or may not be fatal to the application.
    • Warn (default)—Designates potentially harmful situations.
    • Info—Designates informational messages highlighting overall progress of the application.
    • Debug—Designates information events of lower importance.
    • Trace—Designates informational events of very low importance.
    • All—Records all logging levels.

  7. To add a Class Name, in the Class Log Configuration section:
    1. Click Add Row.

      A confirmation message appears.

    2. Click OK.
    3. Enter the Class Name.
      For example, example.schedule.
    4. Select the Log Level from list.

    Note: The CMP server performs no input validation on the entered Class Name or whether the Class Name belongs to the particular component.

  8. Repeat for each debug component you wish to configure a Class Name level log.
  9. Click Save.
The settings are applied to the selected device.